Whirlpool WCD5090J Installation Instructions - Page 2

Description,

Page 2 highlights

Step Description 3. Slowly but firmly pull out the drain hose from its fitting in the pump outlet. Discard the drain hose. Figure 4. Slowly but firmly push the longer drain hose on the fitting of the pump outlet. 5. Plug in machine or connect power after servicing. Insert hose so that the end of the hose extends 4.5" (114 mm) into the standpipe. 6. Floor standpipe drain system: Minimum diameter for a standpipe drain: 2" (51 mm). Top of standpipe must be at least 30" (762 mm) high; install no higher than 36" (910 mm) from bottom of dryer. 7. Be certain not to kink the extension drain hose when moving the dryer into position. 44.5"" (1(11144 mmmm) ) maximum 36" (910 mm) minimum 30" (762 mm) 2

  • 1
  • 2
  • 3
  • 4

Step
Description
Figure
3.
Slowly but firmly pull out the drain hose from its fitting in
the pump outlet. Discard the drain hose.
4.
Slowly but firmly push the longer drain hose on the fitting
of the pump outlet.
5.
Plug in machine or connect power after servicing.
6.
Insert hose so that the end of the hose extends
4.5
"
(114 mm) into the standpipe.
Floor standpipe drain system:
Minimum diameter for a standpipe drain: 2
"
(51 mm). Top
of standpipe must be at least 30
"
(762 mm) high; install no
higher than 36
"
(910 mm) from bottom of dryer.
4.5
"
(114 mm)
4.5"
(114 mm)
maximum 36"
(910 mm)
minimum 30"
(762 mm)
7.
Be certain not to kink the extension drain hose when
moving the dryer into position.
2