Whirlpool WED7300XW Dimension Guide - Page 1
Whirlpool WED7300XW Manual
UPC - 883049202747
View all Whirlpool WED7300XW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Electric Dryer PRODUCT MODEL NUMBERS WED6200S, WED6400S, WED6600V, WED6600W, WED7300X, WED7400X, WED7600X, WED7800X Dryer dimensions OVERALL DIMENSIONS Electrical: This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A timedelay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Exhaust hood styles: B 4" C A (102 mm) 431/2" (1105 mm) 291/4" (743 mm) 29" (737 mm) 221/4" (565 mm) NOTE: Most installations require minimum 5" (127 mm) clearance for exhaust vent with elbow. See "Venting Requirements." Minimum required spacing For cabinet installation, with a door, the minimum ventilation openings in the top are required. 4" (102 mm) 4" (102 mm) Recommended styles: A. Louvered hood B. Box hood Vent System Chart: Number 90º Type of vent elbows 0 Rigid metal 1 Rigid metal 2 Rigid metal 2½" (64 mm) Acceptable styles: C. Angled hood Box /louvered hoods 64 ft. (20 m) 54 ft. (16.5 m) 44 ft. (13.4 m) Angled hoods 58ft. (17.7 m) 48 ft. (14.6 m) 38 ft. (11.6 m) 18"* (457 mm) 1" (25 mm) 29" (737 mm) Recessed area 14" máx.* (356 mm) 48" 2* (310 cm2) 3"* (76 mm) 24" 2* (155 cm2) 3"* (76 mm) 1" (25 mm) 291/4" (743 mm) 5" (127 mm) Side view- closet or confined area Closet door with vents 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) *Required spacing 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10267633A 04/2010