Whirlpool WED7990XG Installation Instructions - Page 17
Connect Vent, Level Dryer
UPC - 883049200354
View all Whirlpool WED7990XG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
6. Turn on cold water faucet 2. Move dryer to final location Check that the water faucets are turned on. 7. Check for leaks Move dryer to final location. Avoid crushing or kinking vent. After dryer is in place, remove cardboard from under the dryer. Level Dryer 1. Level Dryer Place level here Place level here Check for leaks around "Y" connector, faucet, and hoses. NOTE: Replace inlet hoses after 5 years of use to reduce the risk of hose failure. Record hose installation or replacement dates on the hoses for future reference. Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. Connect Vent 1. Connect vent to exhaust outlet Check levelness of dryer from side to side. Repeat from front to back. NOTE: The dryer must be level for the moisture sensing system to operate correctly. Not Level Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp. LEVEL Not Level 17