Whirlpool WED9550WL Installation Instructions - Page 3
Optional Equipment, Location Requirements - steam dryer
UPC - 883049177502
View all Whirlpool WED9550WL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Optional Equipment Refer to your Use and Care guide for information about the accessories available for your dryer. Location Requirements Installation clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions D A B C You will need ■ A location that allows for proper exhaust installation. See "Venting Requirements." ■ A separate 30-amp circuit. ■ If you are using a power supply cord, a grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See "Electrical Requirements." ■ A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered. ■ A level floor with a maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level. ■ For a garage installation, you will need to place the dryer at least 18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to the bottom of the dryer. ■ Steam models only: Cold water faucets located within 4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the cold water supply from your washer using the "Y" connector provided. Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic sensor cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. Steam (Electric or Gas) A 38" (965 mm) B 32 9/16" (827 mm) C 27" (686 mm) D 52 9/16" (1335 mm) Non-Steam (Electric or Gas) 38" (965 mm) 31 1/2" (800 mm) 27" (686 mm) 51 1/2" (1308 mm) NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. Venting Dimensions C A* B Back View Steam (Electric or Gas) Non-Steam (Electric or Gas) A* 1" (25 mm) 1" (25 mm) B 14" (356 mm) 14" (356 mm) C 3 7/16" (87 mm) 3 7/16" (87 mm) * Dimension A is approximate, depending on when the diamond marking on the leveling foot is no longer visible. 3