Whirlpool WED9600TA Dimension Guide - Page 1
Whirlpool WED9600TA - 27" Electric Steam Dryer Manual
UPC - 883049066356
View all Whirlpool WED9600TA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
® Duet® Steam Electronic Electric Dryer PRODUCT MODEL NUMBERS WED9600T Electrical: This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Exhaust venting: Exhaust your dryer to the outside. Four inch (10.2 cm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vent. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust. Water: The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not over tighten. Damage to the coupling can result. OVERALL DIMENSIONS 52-9/16" (133.16 cm) 38" (96.52 cm) Undercounter installation - Dryer only Dimensions shown are for minimum spacing. 0" (0 cm) 38" min. (96.52 cm) 1"* (2.5 cm) *Required spacing 27" (68.6 cm) 1"* (2.5 cm) *32-9/16" (82.65 cm) 27" (68.6 cm) * Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See Installation Instructions, "Venting Requirements." RECESSED AREA AND CLOSET INSTALLATION For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. Dryer on pedestal Dryer only 14" max.* (35.6 cm) 18" min.* (45.72 cm) 48 in.2* (310 cm2) 3"* (7.6 cm) 14" max.* (35.6 cm) 18" min.* (45.72 cm) EXHAUST VENTING Recommended hood styles B A 4" (10.2 cm) 4" (10.2 cm) A. Louvered hood style B. Box hood style Angled hood style is acceptable. 4" (10.2 cm) 2-1/2" (6.4 cm) Number of 90° turns or elbows 0 Type of vent Box or Louvered hoods Rigid metal 64 ft (20 m) Flexible metal 36 ft (11 m) Angled hoods 58 ft (17.7 m) 28 ft (8.5 m) 24 in.2* (155 cm2) 1"* 32-9/16" 5"** (2.5 cm) (82.65 cm) (12.7 cm) A B A. Side view - closet or confined area B. Closet door with vents *Required spacing **For side or bottom venting, 2" (5.1 cm) spacing is allowed. 3"* (7.6 cm) 1" (2.5 cm) 27" (68.6 cm) A 1" 1"* (2.5 cm) (2.5 cm) 32-9/16" 5"** (82.65 cm) (12.7 cm) B A. Recessed area B. Side view - closet or confined area *Required spacing **For side or bottom venting, 2" (5.1 cm) spacing is allowed. 7"* (17.8 cm) 7"* (17.8 cm) Recommended installation spacing for cabinet installation For cabinet installation, with a door, the minimum ventilation openings in the top are required. 9"* (22.9 cm) 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m) 2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) Flexible metal 27 ft (8.2 m) 19 ft (5.8 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) Flexible metal 25 ft (7.6 m) 17 ft (5.2 m) (12.7 5"** cm) 32-9/16" (82.65 cm) 1"* (2.5 cm) (2.5 1" cm) 27" (68.6 cm) 1" (2.5 cm) *Required spacing **For side or bottom venting, 2" (5.1 cm) spacing is allowed. 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4.6 m) NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. Ref. W10136968 09-12-07