Whirlpool WED9620HC Installation Instructions - Page 20
Install Vent System
View all Whirlpool WED9620HC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Long Vent System Chart Number of 90° elbows Type of vent Angled hoods 0 Rigid metal 160 ft. (48.8 m) 1 Rigid metal 150 ft. (45.7 m) 2 Rigid metal 140 ft. (42.7 m) 3 Rigid metal 130 ft. (39.6 m) 4 Rigid metal 120 ft. (36.6 m) To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. Example: An electric model would be DJAV - ELE - XXXXXXX-XXX. A gas model would be DJAV - NAT - XXXXXXXXXX. NOTE: For long vent systems, use of box/louvered hoods will improve venting regardless of length. 2. Connect vent to exhaust hood Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint. Install Vent System 1. Install exhaust hood Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. 20