Whirlpool WEE510S0FS Installation Guide - Page 9

Wire Connection: Power Supply Cord, Wire Connection: Power Supply Cord - range

Page 9 highlights

3-Wire Connection: Power Supply Cord Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord. 1. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. A B 4-Wire Connection: Power Supply Cord Use this method for: ■■ New branch-circuit installations (1996 NEC) ■■ Mobile homes ■■ Recreational vehicles ■■ In an area where local codes prohibit grounding through the neutral 1. Cut out and remove part of metal ground strap, as shown. A B C C D A. Terminal block B. Ground-link screw C. UL listed strain relief D. Power supply cord wires - large opening 2. Use ³⁄8" (1.0 cm) nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10-32 hex nuts. A. Metal ground strap B. Discard C. Ground-link screw 2. Use a Phillips screwdriver to remove the ground-link screw from the back of the range. Save the ground-link screw and the end of the ground link under the screw. 3. Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. A B A E D B C A. 10-32 hex nut B. Line 2 (red) wire C. Ground-link screw D. Neutral (white) wire E. Line 1 (black) wire 3. Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts. 4. Firmly tighten hex nuts. NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40- or 50-amps that is marked for use with nominal 1³⁄8" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges. 5. Tighten strain relief screws. IMPORTANT: Verify the tightness of the hex nuts. 6. Replace lower access cover. C D A. Terminal block B. Ground-link screw C. UL listed strain relief D. Power supply cord wires 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

9
3-Wire Connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1.
Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack
to easily attach the wiring to the terminal block.
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires - large opening
2.
Use ³⁄
8
" (1.0 cm) nut driver to connect the neutral (white) wire
to the center terminal block post with one of the 10-32
hex nuts.
A. 10–32 hex nut
B. Line 2 (red) wire
C. Ground-link screw
D. Neutral (white) wire
E. Line 1 (black) wire
3.
Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
4.
Firmly tighten hex nuts.
NOTE:
For power supply cord replacement, use only a
power cord rated at 250 volts minimum, 40- or 50-amps
that is marked for use with nominal 1³⁄
8
" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5.
Tighten strain relief screws.
IMPORTANT:
Verify the tightness of the hex nuts.
6.
Replace lower access cover.
4-Wire Connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1.
Cut out and remove part of metal ground strap, as shown.
A. Metal ground strap
B. Discard
C. Ground-link screw
2.
Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3.
Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack
to easily attach the wiring to the terminal block.
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires
A
B
D
C
A
B
C
D
E
A
B
C
A
B
D
C