Whirlpool WRF550CDHZ Performance Data Sheet - Page 2

Application Guidelines/Water Supply Parameters, Feb-2021 09:19:39 EST | RELEASED

Page 2 highlights

Linuron 140 ± 20% 20 ng/L >96.3% 96.3% Meprobamate 400 ± 20% 60 ng/L >95.2% 95.2% Metolachor 1400 ± 20% 200 ng/L >98.7% 98.7% Trimethoprim 140 ± 20% 20 ng/L >96.6% 96.5% Bisphenol 2000 ± 20% 300 ng/L >99.1% 99.1% Estrone 140 ± 20% 20 ng/L >96.6% 96.4% Nonylphenol 1400 ± 20% 200 ng/L >96.7% 96.6% Ibuprofen 400 ± 20% 60 ng/L >95.5% 95.3% Naproxen 140 ± 20% 20 ng/L >96.8% 96.7% Phenytoin 200 ± 20% 30 ng/L >95.5% 95.5% Turbidity 11 NTU ± 10% 0.5 NTU 98.8% 98.2% Chlorobenzene 2.0 ± 10% 0.1 mg/ L >99.9% 99.9% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.70 gpm (2.65 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters) with PID, 100 gallons (379 liters) without PID. The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental contaminants compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/ perception of drinking water quality. � For installation, operation, and maintenance instructions please � The product is for cold water use only. refer to the Owners Manual. � The water system must be installed in compliance with state and � It is essential that operational, maintenance, and filter replacement local laws and regulations. requirements be carried out for the product to perform as advertised. Property damage can occur if all instructions are not followed. � Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on � The disposable cartridge must be changed at least every 6 months. disinfected waters that may contain filterable cysts. EPA Est. No. � Use replacement filter UKF8001, Part # EDR4RXD1/EDR4RXD1B. 69625-CT-001 2018 suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices � Refer to the "Warranty" for the Manufacturer's limited warranty, are subject to change without notice. name and telephone number. � The filter monitor system measures the amount of water that passes through the filter and alerts you when it is time to replace Application Guidelines/Water Supply Parameters the filter. To learn how to check the water filter status, see "Using Water Supply Potable City or Well the Controls" or "Water Filtration System" in the User Instructions Water Pressure or User Guide. 30 psi - 120 psi (207 kPa - 827 kPa) � After changing the water filter, flush the water system. See "Water Water Temperature 33°F - 100°F (0.6°C - 37.8°C and Ice Dispensers" or "Water Dispenser" in the User Instructions or User Guide. Service Flow Rate 0.70 GPM (2.65 L/min.) @ 60 psi. (413.7 kPa) � These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual � Your water filtration system will withstand up to 120 pounds per performance may vary. square inch (psi) water pressure. If your water supply is higher than 80 psi, install a pressure reducing valve before installing the water filtration system. *Class I particle size: >0.5 to 1 um †Based on the use of Cryptosporidium parvum oocysts ††Fibers greater than 10 um in length ®NSF is a registered trademark of NSF International. 2 05-Feb-2021 09:19:39 EST | RELEASED In some European factories the letter "W" of the part code mentioned herein will be automatically replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Linuron
140 ± 20%
20 ng/L
>96.3%
96.3%
Meprobamate
400 ± 20%
60 ng/L
>95.2%
95.2%
Metolachor
1400 ± 20%
200 ng/L
>98.7%
98.7%
Trimethoprim
140 ± 20%
20 ng/L
>96.6%
96.5%
Bisphenol
2000 ± 20%
300 ng/L
>99.1%
99.1%
Estrone
140 ± 20%
20 ng/L
>96.6%
96.4%
Nonylphenol
1400 ± 20%
200 ng/L
>96.7%
96.6%
Ibuprofen
400 ± 20%
60 ng/L
>95.5%
95.3%
Naproxen
140 ± 20%
20 ng/L
>96.8%
96.7%
Phenytoin
200 ± 20%
30 ng/L
>95.5%
95.5%
Turbidity
11 NTU ± 10%
0.5 NTU
98.8%
98.2%
Chlorobenzene
2.0 ± 10%
0.1 mg/ L
>99.9%
99.9%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.70 gpm (2.65 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C
to 22°C). Rated service capacity = 200 gallons (757 liters) with PID, 100 gallons (379 liters) without PID.
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds
can affect the public acceptance/ perception of drinking water quality.
For installation, operation, and maintenance instructions please
refer to the Owners Manual.
It is essential that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as
advertised. Property damage can occur if all instructions are not
followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter UKF8001, Part # EDR4RXD1/EDR4RXD1B.
2018 suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices
are subject to change without notice.
The filter monitor system measures the amount of water that
passes through the filter and alerts you when it is time to replace
the filter. To learn how to check the water filter status, see “Using
the Controls” or “Water Filtration System” in the User Instructions
or User Guide.
After changing the water filter, flush the water system. See “Water
and Ice Dispensers” or “Water Dispenser” in the User Instructions
or User Guide.
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts. EPA Est. No.
69625-CT-001
Refer to the “Warranty” for the Manufacturer’s limited warranty,
name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Potable City or Well
Water Pressure
30 psi - 120 psi (207 kPa - 827
kPa)
Water Temperature
33°F - 100°F (0.6°C - 37.8°C
Service Flow Rate
0.70 GPM (2.65 L/min.) @ 60 psi.
(413.7 kPa)
Your water filtration system will withstand up to 120 pounds per
square inch (psi) water pressure. If your water supply is higher
than 80 psi, install a pressure reducing valve before installing the
water filtration system.
*Class I particle size: >0.5 to 1 um
†Based on the use of Cryptosporidium parvum oocysts
††Fibers greater than 10 um in length
®
NSF is a registered trademark of NSF International.
05-Feb-2021 09:19:39 EST | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")