Whirlpool WRF767SDHZ Owners Manual - Page 38
Performance Data Sheets
View all Whirlpool WRF767SDHZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
PERFORMANCE DATA SHEETS Water Filtration System Model P9WB2L/P9RFWB2L Capacity 200 Gallons (757 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42, Standard 53, Standard 401, and CSA B483.1 for the reduction of contaminants specified on the Performance Data Sheet. This system has been tested according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standa rds 42, 53, 401, and CSA B483.1. Substance Reduction Aesthetic Influent Challenge Concentration Maximum Permissable Product Average % Reduction Effects Water Concentration Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 9 7.0% Particulate Class I* At least 10,000 particles/mL 85% reduction >99.9% Contaminant Reduction Influent Challenge Concentration Maximum Permissable Product Average % Reduction Water Concentration Lead: @ pH 6.5 / @ pH 8.5 0.15 mg/L± 10% 0.010 mg/L >99.3%/98.6% Benzene 0.015 mg/L ± 10% 0.005 mg/L 93.8% p-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.8% Carbofuran 0.08 mg/L ± 10% 0.040 mg/L 81.9% Toxaphene 0.015 ± 10% 0.003 mg/L >95% Atrazine 0.009 mg/L ± 10% 0.003 mg/L 87.0% Asbestos 107 to 108 fibers/L†† 99% >99% Live Cysts† 50,000/L min. 99.95% >99.99% Turbidity 11 NTU ± 10% 0.5 NTU 96.9% Lindane 0.002 ± 10% 0.0002 mg/L >99.2% Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.6% O-Dichlorobenzene 1.8 mg/L ± 10% 0.60 mg/L 92.3% Ethylbenzene 2.1 mg/L ± 10% 0.70 mg/L 86.9% 1,2,4-Trichlorobenzene 0.210 mg/L ± 10% 0.07 mg/L >99.8% 2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 88.5% Styrene 2.0 mg/L ± 10% 0.1 mg/L 99.6% Toluene 3.0 mg/L ± 10% 1.0 mg/L 93.5% Endrin 0.006 mg/L ± 10% 0.002 mg/L 81.7% Atenolol 200 ± 20% 30 ng/L 95.7% Trimethoprim 140 ± 20% 20 ng/L 96.1% Linuron 140 ± 20% 20 ng/L 96.3% Estrone 140 ± 20% 20 ng/L 95.3% Nonylphenol 1400 ± 20% 200 ng/L 95.5% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality. ■■ It is important that operational, maintenance, and filter replacement ■■ The water system must be installed in compliance with state and requirements be carried out for the product to perform as advertised. local laws and regulations. Property damage can occur if all instructions are not followed. ■■ The disposable cartridge must be changed at least every 6 months. ■■ Use replacement filter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B. 2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices are subject to change without notice. ■■ The filter monitor system measures the amount of water that passes through the filter and alerts you when it is time to replace the filter. Refer to the "Using the Controls" or "Water Filtration System" section ■■ Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. EPA Est. No. 082047-TWN-001 ■■ Refer to the "Warranty" section (in the User Instructions or User Guide) for the Manufacturer's limited warranty, name, and telephone number. (in the User Instructions or User Guide) to learn how to check the water filter status. Application Guidelines/Water Supply Parameters ■■ After changing the water filter, flush the water system. See "Water and Ice Dispensers" or "Water Dispenser" in the User Instructions or User Guide. ■■ These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual Water Supply Water Pressure Water Temperature Service Flow Rate Potable City or Well 35 - 120 psi (241 - 827 kPa) 33° - 100°F (1° - 38°C) 0.75 gpm (2.84 L/min.) @ 60 psi performance may vary. ■■ The product is for cold water use only. *Class I particle size: >0.5 to