PERFORMANCE DATA SHEET Water Filtration System Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Live Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D. This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53. Substance Reduction Aesthetic Effects NSF Reduction Average Requirements Influent Influent Challenge Concentration Maximum Minimum % Average % Effluent Reduction Reduction Chlorine Taste/Odor 50% reduction 2.0 mg/L 2.0 mg/L ± 10% 0.20 mg/L 97 97.2 Particulate Class I* 85% reduction 7,300,000 #/mL At least 10,000 particles/mL 75,000 #/mL** 99 99.4 Contaminant Reduction NSF Reduction Average Requirements Influent Influent Challenge Concentration Maximum Minimum % Average % Effluent Reduction Reduction Live Cysts† 99.95% 160,000/L 50,000/L min. 54/L† 99.97 99.99 Asbestos 99% 87 MFL 107 to 108 fibers/L†† 0.17 MFL 99 99 Lead: @ pH 6.5 0.010 mg/L 0.010 0.160 mg/L 0.140 0.15 mg/L ± 10% 0.001 mg/L 99.4 99.4 Lead: @ pH 8.5 mg/L mg/L 0.15 mg/L ± 10% 0.005 mg/L 98.6 98.6 Lindane 0.0002 mg/L 0.0019 mg/L 0.002 mg/L ± 10% 0.00002 mg/L 98.9 99 Toxaphene 0.003 mg/L 0.014 mg/L 0.015 mg/L ± 10% 0.001 mg/L 93 93 Atrazine 0.003 mg/L 0.0094 mg/L 0.009 mg/L ± 10% 0.0005 mg/L 94.5 94.7 2,4 - D 0.07 mg/L 0.220 mg/L 0.210 mg/L ± 10% 0.028 mg/L 87.5 96.1 Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). ■■ It is important that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. Property damage can occur if all instructions are not followed. ■■ Use replacement filter according you filtration system, see"Ice and Water" in the User Guide. Water Filter: Water Filtration System Style 1 - Order Part # EDR1RXD1 Water Filtration System Style 2 - Order Part # EDR2RXD1 When the water filter status changes from TURN OFF to RED light on your control panel, it is recommended that you replace the filter. ■■ After changing the water filter, flush the water system. See "Water and Ice Dispensers" or "Water Dispenser" in the User Instructions or User Guide. ■■ These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary. ■■ The product is for cold water use only. ■■ The water system must be installed in compliance with state and local laws and regulations. ■■ Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. ■■ Refer to the "Warranty" section (in the User Instructions or User Guide) for the Manufacturer's name, address and telephone number. ■■ Refer to the "Warranty" section (in the User Instructions or User Guide) for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33° - 100°F (0.6° - 37.8°C) 0.5 gpm (1.9 Lpm) @ 60 psi *Class I particle size: >0.5 to

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

17
PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class I*
50% reduction
85% reduction
2.0 mg/L
7,300,000 #/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.20 mg/L
75,000 #/mL**
97
99
97.2
99.4
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Minimum %
Reduction
Average %
Reduction
Live Cysts
99.95%
160,000/L
50,000/L min.
54/L
99.97
99.99
Asbestos
99%
87 MFL
10
7
to 10
8
fibers/L
††
0.17 MFL
99
99
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L 0.010
mg/L
0.160 mg/L 0.140
mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.005 mg/L
99.4
98.6
99.4
98.6
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 mg/L ± 10%
0.00002 mg/L
98.9
99
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 mg/L ± 10%
0.001 mg/L
93
93
Atrazine
0.003 mg/L
0.0094 mg/L
0.009 mg/L ± 10%
0.0005 mg/L
94.5
94.7
2,4 - D
0.07 mg/L
0.220 mg/L
0.210 mg/L ± 10%
0.028 mg/L
87.5
96.1
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is important that operational, maintenance, and filter
replacement requirements be carried out for the product
to perform as advertised. Property damage can occur if all
instructions are not followed.
Use replacement filter according you filtration system, see“Ice
and Water” in the User Guide.
Water Filter:
Water Filtration System Style 1 - Order Part # EDR1RXD1
Water Filtration System Style 2 - Order Part # EDR2RXD1
When the water filter status changes from TURN OFF to
RED light on your control panel, it is recommended that you
replace the filter.
After changing the water filter, flush the water system. See
“Water and Ice Dispensers” or “Water Dispenser” in the User
Instructions or User Guide.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state
and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the “Warranty” section (in the User Instructions
or User Guide) for the Manufacturer’s name, address and
telephone number.
Refer to the “Warranty” section (in the User Instructions or
User Guide) for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Based on the use of Cryptosporidium parvum oocysts
††
Fibers greater than 10 um in length
NSF is a registered trademark of NSF International.