Whirlpool WTW4850BW Dimension Guide - Page 2

Electrical Requirements, Drain System - parts

Page 2 highlights

ELECTRICAL REQUIREMENTS A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided. DRAIN SYSTEM Drain system can be installed using a floor drain, wall standpipe, floor standpipe, or laundry tub. Select method you need. Floor standpipe drain system Floor drain system 4.5" (114 mm) 39" (990 mm) Minimum diameter for a standpipe drain: 2" (51 mm). Minimum carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe must be at least 39" (990 mm) high; install no higher than 96" (2.44 m) from bottom of washer. If you must install higher than 96" (2.44 m), you will need a sump pump system. Wall standpipe drain system Floor drain system requires a Siphon Break Kit (Part Number 285834), 2 Connector Kits (Part Number 285835), and an Extension Drain Hose (Part Number 285863) that may be purchased separately. To order, please see toll-free phone numbers in your Use and Care Guide. Minimum siphon break: 28" (710 mm) from bottom of washer. (Additional hoses may be needed.) Laundry tub drain system 4.5" (114 mm) See requirements for floor standpipe drain system. 4.5" (114 mm) 39" (990 mm) Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 39" (990 mm) above floor; install no higher than 96" (2.44 m) from bottom of washer. IMPORTANT: To avoid siphoning, no more than 4.5" (114 mm) of drain hose should be inside standpipe or below the top of wash tub. Secure drain hose with cable tie. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.

  • 1
  • 2

Because Whirlpool Corporation policy includes a continuous commitment to improve
Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specifications without notice.
Instructions packed with product. Specifications subject to change without notice.
ELECTRICAL REQUIREMENTS
DRAIN SYSTEM
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is
recommended that a separate circuit serving only this appliance be provided.
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe
must be at least 39" (990 mm) high; install no higher than
96" (2.44 m) from bottom of washer. If you must install higher
than 96" (2.44 m), you will need a sump pump system.
Wall standpipe drain system
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at
least 39" (990 mm) above floor; install no higher than 96" (2.44 m)
from bottom of washer.
IMPORTANT:
To avoid siphoning, no more than 4.5" (114 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with cable tie.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. To order, please see toll-free phone
numbers in your Use and Care Guide. Minimum siphon break:
28" (710 mm) from bottom of washer. (Additional hoses may
be needed.)
Floor standpipe drain system
4.5"
(114 mm)
39"
(990 mm)
4.5"
(114 mm)
39"
(990 mm)
4.5"
(114 mm)
See requirements for floor standpipe drain system.
Drain system can be installed using a floor drain, wall standpipe,
floor standpipe, or laundry tub. Select method you need.