Yamaha 700 Reference Booklet - Page 26
< Table 1-7 >, Refer to the XG Ef. Parameter List
UPC - 027108933412
View all Yamaha 700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
MIDI Data Format 03 0n 30 2 03 0n 32 2 03 0n 34 2 03 0n 36 2 03 0n 38 2 03 0n 3A 2 03 0n 3C 2 03 0n 3E 2 03 0n 40 2 03 0n 42 2 TOTAL SIZE 14 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F 00..7F Ins. Param.1 MSB Ins. Param.1 LSB Ins. Param.2 MSB Ins. Param.2 LSB Ins. Param.3 MSB Ins. Param.3 LSB Ins. Param.4 MSB Ins. Param.4 LSB Ins. Param.5 MSB Ins. Param.5 LSB Ins. Param.6 MSB Ins. Param.6 LSB Ins. Param.7 MSB Ins. Param.7 LSB Ins. Param.8 MSB Ins. Param.8 LSB Ins. Param.9 MSB Ins. Param.9 LSB Ins. Param.10 MSB Ins. Param.10 LSB Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List Refer to the Ef. Parameter List For effect types that do not require MSB, the Parameters for Address 02-0B will be received. Address 30-42 will not be received. For effect types that require MSB, the Parameters for Address 30-42 will be received. Address 02-0B will not be received. When Bulk Dumps that include Effect Type data are transmitted, the Parameters for Address 02 - 0B will always be transmitted. But, effects that require MSB, when the bulk dump is received the Parameters for Address 02 - 0B will not be received. n = Insertion Effect No. (0 - 2) The INSERTION EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value. When a Parameter Request or Bulk Request message is received, the currently set value is always transmitted. < Table 1-7 > MIDI PARAMETER CHANGE TABLE (SPECIAL EFFECT) (CVP-109/107/700) Address Size Data Parameter (H) (H) (H) 04 00 00 2 00 - 7F Insertion Effect Type MSB 00 - 7F Insertion Effect Type LSB 02 1 00 - 7F Insertion Effect Parameter1 03 1 00 - 7F Insertion Effect Parameter2 04 1 00 - 7F Insertion Effect Parameter3 05 1 00 - 7F Insertion Effect Parameter4 06 1 00 - 7F Insertion Effect Parameter5 07 1 00 - 7F Insertion Effect Parameter6 08 1 00 - 7F Insertion Effect Parameter7 09 1 00 - 7F Insertion Effect Parameter8 0A 1 00 - 7F Insertion Effect Parameter9 0B 1 00 - 7F Insertion Effect Parameter10 0C 1 00 - 7F Insertion Effect Part 0D 1 0E 1 0F 1 10 1 11 1 TOTAL SIZE 12 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F MW Insertion Control Depth BEND Insertion Control Depth CAT Insertion Control Depth AC1 Insertion Control Depth AC2 Insertion Control Depth Description Default Refer to the XG Effect Map 00 : basic type Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Part1...16(0...15) AD1(64) OFF(16...63, 65...127) Don't care Don't care Don't care Don't care Don't care 04 00 14 1 15 1 TOTAL SIZE 2 00 - 7F 00 - 7F Unique Insertion Effect External Control CH1(Harmony Channel) Unique Insertion Effect External Control CH2 (MELODY CHANNEL) 1...16(0...15), off(127) 1...16(0...15), off(127) 04 00 20 1 21 1 22 1 23 1 24 1 25 1 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F 00 - 7F Insertion Effect Parameter11 Insertion Effect Parameter12 Insertion Effect Parameter13 Insertion Effect Parameter14 Insertion Effect Parameter15 Insertion Effect Parameter16 Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List Refer to the XG Ef. Parameter List TOTAL SIZE 6 Insertion Effect Type MSB: Assigns the Harmony Mode. If the value is not a Harmony Mode value, the Harmony function will be OFF and the input signal will be transmitted as is. Insertion Effect Type LSB: Assigns the Harmony Kit. If the value is not an existing harmony kit value, don't care. Harmony Channel: Harmony control channel. Melody Channel: Melody play channel. When both are received, the last message received will take priority. For example, when the Melody Channel is 3 and the Harmony Channel 3 message is received, the Melody Channel will be OFF and the Harmony Channel will be 3. Note) The SPECIAL EFFECT Parameter cannot be reset to its factory settings with XG SYSTEM ON or XG ALL PARAMETER RESET, there is no default value. When a request message is received, the currently set value is always transmitted. 26 CVP-109/107/105/103/700