Other MIDI Functions

Page 32 highlights

MIDI Functions Other MIDI Functions The MIDI functions listed to the right are engaged by holding down the [MIDI/TRANSPOSE] button and pressing the corresponding voice selector. Full details are given in the following pages. MIDI FUNCTION CHART Function Local Control ON/OFF Program Change ON/OFF Control Change ON/OFF Multi-Timbre Mode MIDI Split & Left Local OFF MIDI Split & Right Local OFF Panel Data Transmit CLP-156 Voice Selector [PIANO 1] [PIANO 2] [CLAVINOVA TONE] [E.PIANO ] [HARPSICHORD] [VIBES] [STRINGS] q Local Control ON/OFF MIDI OUT MIDI IN Sequence Tone Generator Recorder Played from Clavinova keyboard. MIDI IN MIDI OUT Clavinova Local control OFF. Played from MIDI Sequencer. MIDI/ TRANSPOSE CLAVINO PIANO 1 PIANO 2 TONE PIANO 1 = Local Control OFF PIANO 1 = Local Control ON "Local Control" refers to the fact that, normally, the Clavinova keyboard controls its internal tone generator, allowing the internal voices to be played directly from the keyboard. This situation is "Local Control ON" since the internal tone generator is controlled locally by its own keyboard. Local control can be turned OFF, however, so that the Clavinova keyboard does not play the internal voices, but the appropriate MIDI information is still transmitted via the MIDI OUT connector when notes are played on the keyboard. At the same time, the internal tone generator responds to MIDI information received via the MIDI IN connector. This means that while an external MIDI sequence recorder, for example, plays the Clavinova's internal voices, an external tone generator can be played from the Clavinova keyboard. Z Hold down the [MIDI/TRANSPOSE] button. X Press the [PIANO 1] voice selector. If the PIANO 1 LED is lit when the [PIANO 1] voice selector is pressed, you have turned local control OFF. If the PIANO 1 LED is not lit when the [PIANO 1] voice selector is pressed, you have turned local control ON. C Release the [MIDI/TRANSPOSE] button. q Program Change ON/OFF Normally the Clavinova will respond to MIDI program change numbers received from an external keyboard or other MIDI device, causing the correspondingly numbered Clavinova voice to be selected. The Clavinova will normally also send a MIDI program change number whenever one of its voices is selected, causing the correspondingly numbered voice or program to be selected on the external MIDI device if the device is set up to receive and respond to MIDI program change numbers. This function makes it possible to cancel program change number reception and transmission so that voices can be selected on the Clavinova without affecting the external MIDI device, and vice versa. MIDI/ TRANSPOSE CLAVINO PIANO 1 PIANO 2 TONE PIANO 2 = Program Change OFF PIANO 2 = Program Change ON Z Hold down the [MIDI/TRANSPOSE] button. X Press the [PIANO 2] voice selector. If the PIANO 2 LED is lit when the [PIANO 2] voice selector is pressed, you have turned program change reception/transmission OFF. If the PIANO 2 LED is not lit when the [PIANO 2] voice selector is pressed, you have turned program change reception/transmission ON. C Release the [MIDI/TRANSPOSE] button. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

32
MIDI/
TRANSPOSE
PIANO 2
PIANO 2
PIANO 1
PIANO 2
CLAVINO
TONE
MIDI/
TRANSPOSE
PIANO 1
PIANO 1
PIANO 1
PIANO 2
CLAVINO
TONE
MIDI Functions
MIDI FUNCTION CHART
Function
CLP-156 Voice Selector
Local Control ON/OFF
[PIANO 1]
Program Change ON/OFF
[PIANO 2]
Control Change ON/OFF
[CLAVINOVA TONE]
Multi-Timbre Mode
[E.PIANO ]
MIDI Split & Left Local OFF
[HARPSICHORD]
MIDI Split & Right Local OFF
[VIBES]
Panel Data Transmit
[STRINGS]
Other MIDI Functions
The MIDI functions listed to the right are engaged by
holding down the
[MIDI/TRANSPOSE]
button and press-
ing the corresponding voice selector. Full details are given
in the following pages.
Normally the Clavinova will respond to MIDI program change numbers received from an external keyboard
or other MIDI device, causing the correspondingly numbered Clavinova voice to be selected. The Clavinova
will normally also send a MIDI program change number whenever one of its voices is selected, causing the
correspondingly numbered voice or program to be selected on the external MIDI device if the device is set up to
receive and respond to MIDI program change numbers.
This function makes it possible to cancel program change number reception and transmission so that voices
can be selected on the Clavinova without affecting the external MIDI device, and vice versa.
Z
Hold down the
[MIDI/TRANSPOSE]
button.
X
Press the
[PIANO 2]
voice selector. If the PIANO 2 LED is lit when
the
[PIANO 2]
voice selector is pressed, you have turned program
change reception/transmission OFF. If the PIANO 2 LED is not lit
when the
[PIANO 2]
voice selector is pressed, you have turned pro-
gram change reception/transmission ON.
C
Release the
[MIDI/TRANSPOSE]
button.
Local Control ON/OFF
Program Change ON/OFF
= Local Control OFF
= Local Control ON
= Program Change OFF
= Program Change ON
“Local Control” refers to the fact that, normally, the Clavinova keyboard
controls its internal tone generator, allowing the internal voices to be played
directly from the keyboard. This situation is “Local Control ON” since the
internal tone generator is controlled locally by its own keyboard.
Local control can be turned OFF, however, so that the Clavinova key-
board does not play the internal voices, but the appropriate MIDI informa-
tion is still transmitted via the MIDI OUT connector when notes are played
on the keyboard. At the same time, the internal tone generator responds to
MIDI information received via the MIDI IN connector. This means that
while an external MIDI sequence recorder, for example, plays the Clavino-
va’s internal voices, an external tone generator can be played from the
Clavinova keyboard.
Z
Hold down the
[MIDI/TRANSPOSE]
button.
X
Press the
[PIANO 1]
voice selector. If the PIANO 1 LED is lit when
the
[PIANO 1]
voice selector is pressed, you have turned local control
OFF. If the PIANO 1 LED is not lit when the
[PIANO 1]
voice selector
is pressed, you have turned local control ON.
C
Release the
[MIDI/TRANSPOSE]
button.
Tone Generator
MIDI IN
MIDI OUT
Sequence
Recorder
MIDI IN
MIDI OUT
Played from Clavinova
keyboard.
Clavinova
Local control OFF. Played from
MIDI Sequencer.