Yamaha CVP-201 Reference Booklet - Page 15
Channel Mode Messages, 3 Registered Parameter Numberrpn
View all Yamaha CVP-201 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
• Portamento time is fixed to 0 when the PORTAMENTO CONTROL is used. • HARMONIC CONTENT applies adjustment to the resonance value that is set by the voice. This parameter specifies relative change with the value of 64 producing 0 adjustment. As values get higher the sound becomes increasingly eccentric. Note that for some voices the effective parameter range is narrower than the legal parameter range. • RELEASE TIME applies adjustment to the envelope release time set by the voice. This parameter specifies relative change with the value of 64 producing 0 adjustment. • ATTACK TIME applies adjustment to the envelope attack time set by the voice. This parameter specifies relative change with the value of 64 producing 0 adjustment. • BRIGHTNESS applies adjustment to the cut-off frequency set by the voice. This parameter specifies relative change with the value of 64 producing 0 adjustment. Lower voices produce a softer sound. For some voices the effective parameter range is narrower than the legal parameter range. (3-2) CHANNEL MODE MESSAGES STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER CONTROL NUMBER 0ccccccc c = CONTROL NUMBER CONTROL VALUE 0vvvvvvv v = DATA VALUE (3-2-1) ALL SOUND OFF (Receive only) (CONTROL NUMBER = 78H , DATA VALUE = 0) Switches off all sound from the channel. Reset Note On and Hold On conditions established by Channel Messages. (3-2-2) RESET ALL CONTROLLERS (Receive only) (CONTROL NUMBER = 79H , DATA VALUE = 0) Resets controllers as follows. PITCH BEND CHANGE AFTER TOUCH MODULATION EXPRESSION SUSTAIN SOSTENUTO SOFT PEDAL NRPN RPN PORTAMENT CONTROL PORTAMENTO 0 (Center) 0 (min.) 0 (min.) 127 (max.) 0 (off) 0 (off) 0 (off) Sets number to null. (Internal data remains unchanged) Sets number to null. (Internal data remains unchanged) Resets portamento source note number 0 (off) (3-2-3) ALL NOTES OFF (Receive only) (CONTROL NUMBER = 7BH , DATA VALUE = 0) Switches off all of the channel's "on" notes. However, any notes being held by SUSTAIN or SOSTENUTO continue to sound until SUSTAIN/SOSTENUTO goes off. (3-2-4) OMNI OFF (Receive only) (CONTROL NUMBER = 7CH , DATA VALUE = 0) Same processing as for All Notes Off. (3-2-5) OMNI ON (Receive only) (CONTROL NUMBER = 7DH , DATA VALUE = 0) Same processing as for All Notes Off. Omni On is not executed. (3-2-6) MONO (Receive only) (CONTROL NUMBER = 7EH , DATA VALUE = 0) Same processing as for All Notes Off. If the 3rd byte is in a range of 0-16 the corresponding channel will be changed to Mode 4 (m=1). (3-2-7) POLY (Receive only) (CONTROL NUMBER = 7FH , DATA VALUE = 0) Same processing as for All Sounds Off and the corresponding channel will be changed to Mode 3. (3-3) REGISTERED PARAMETER NUMBER(RPN) STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER RPN LSB 01100100(64H) RPN LSB NUMBER 0ppppppp p = RPN LSB (refer to the list below) RPN MSB 01100101(65H) RPN MSB NUMBER 0qqqqqqq q = RPN MSB (refer to the list below) DATA ENTRY MSB 00000110(06H) DATA VALUE 0mmmmmmm m = Data Value DATA ENTRY LSB 00100110(26H) DATA VALUE 0lllllll l = Data Value First appoints the parameter for RPN MSB/LSB, then sets the parameter value for data entry MSB/LSB. RPN LSB MSB 00H 00H 01H 00H 02H 00H 7FH 7FH D.ENTRY MSB LSB mmH - mmH llH mmH - -- PARAMETER NAME DATA RANGE PITCH BEND SENSITIVITY 00H-18H (0 - 24 semitones) FINE TUNE {mmH,llH} = {00H,00H}-{40H,00H}-{7FH,7FH} (-8192*100/8192) - 0 - (+8192*100/8192) COARSE TUNE 28H - 40H - 58H (-24 - 0 - +24 semitones) NULL Clears the current RPN number setting. Does not change the internal parameter settings. (3-4) NON-REGISTERED PARAMETER NUMBER(NRPN) (Receive only) STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER NRPN LSB 01100010(62H) NRPN LSB NUMBER 0ppppppp p = NRPN LSB (refer to the list below) NRPN MSB 01100011(63H) NRPN MSB NUMBER 0qqqqqqq q = NRPN MSB (refer to the list below) DATA ENTRY MSB 00000110(06H) DATA VALUE 0mmmmmmm m = Data Value First appoints the parameter for NRPN MSB/LSB, then sets the parameter value for data entry MSB/LSB. NRPN MSB LSB 01H 08H 01H 09H 01H 0AH 01H 20H 01H 21H 01H 63H 01H 64H 01H 66H 14H rrH 15H rrH 16H rrH 17H rrH 18H rrH 19H rrH 1AH rrH 1CH rrH 1DH rrH 1EH rrH 1FH rrH D.ENTRY MSB LSB mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - mmH - PARAMETER NAMEDATA RANGE VIBRATO RATE 00H - 40H - 7FH (-64 - 0 - +63) VIBRATO DEPTH 00H - 40H - 7FH (-64 - 0 - +63) VIBRATO DELAY 00H - 40H - 7FH (-64 - 0 - +63) FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63) FILTER RESONANCE 00H - 40H - 7FH (-64 - 0 - +63) EG ATTACK TIME 00H - 40H - 7FH (-64 - 0 - +63) EG DECAY TIME 00H - 40H - 7FH (-64 - 0 - +63) EG RELEASE 00H - 40H - 7FH (-64 - 0 - +63) DRUM FILTER CUTOFF FREQ. 00H - 40H - 7FH (-64 - 0 - +63) DRUM FILTER RESONANCE 00H - 40H - 7FH (-64 - 0 - +63) DRUM AEG ATTACK RATE 00H - 40H - 7FH (-64 - 0 - +63) DRUM AEG DECAY RATE 00H - 40H - 7FH (-64 - 0 - +63) DRUM PITCH COARSE 00H - 40H - 7FH (-64 - 0 - +63) DRUM PITCH FINE 00H - 40H - 7FH (-64 - 0 - +63) DRUM LEVEL 00H - 7FH (0 - max.) DRUM PANPOT 00H ,01H - 40H - 7FH (random,left - center - right) DRUM REVERB SEND LEVEL 00H - 7FH (0 - max.) DRUM CHORUS SEND LEVEL 00H - 7FH (0 - max.) DRUM VARIATION SEND LEVEL 00H - 7FH (0 - max.) The MSB 14H-1FH (for drums) message is received when multi-part parameters PART MODE = DRUMS1...2. rrH : drum instrument note number (3-5) SYSTEM REALTIME MESSAGES (3-5-1) MIDI CLOCK STATUS 11111000 (F8H) Transmission: 96 clocks per measure are transmitted. Reception: If the instrument's clock is set to external, after FAH is received from the external device the instrument's clock will sync with the 96 beats per measure received from the external device. Decides whether the internal clock, or Timing Clocks received via the MIDI IN will be used. (3-5-2) START STATUS 11111010 (FAH) Transmission: Transmitted when instrument's Rhythm or Song playback is started. Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will start. (3-5-3) STOP STATUS 11111100 (FCH) Transmission: Transmitted when instrument's Rhythm or Song playback is stopped. Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will stop. CVP-201 15