WORD CLOCK OUT/IN connectors, CONSOLE NETWORK OUT/IN connectors

Page 11 highlights

 WORD CLOCK OUT/IN connectors These are BNC connectors used to transmit/receive word clock signals to/from an external device. The WORD CLOCK IN connector is internally terminated by a 75 ohm resistor.  TC IN jack This balanced XLR-3-31-type female jack accepts time code signals from the connected external device. Male XLR plug 1 (ground) 3 (Cold) 2 (Hot) NETWORK connector This RJ-45 connector enables you to connect an external device via an Ethernet cable (CAT5 or higher). NOTE • Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable's shield by conductive tape or comparable means. • The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ45 plugs can also be used. • Cable length can span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.  LINK/ACT indicator This indicator lights up or flashes green, depending on the connection status. When the indicator lights up, the link has been established. When the indicator flashes, data is being transmitted. ! CONSOLE NETWORK OUT/IN connectors These RJ-45 connectors allow this unit to be connected to a control surface via Ethernet cables (CAT5e or higher recommended). NOTE • Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable's shield by conductive tape or comparable means. • The use of Ethernet cables with Neutrik etherCON CAT5e compatible RJ-45 plugs is recommended. Standard RJ45 plugs can also be used. • Cable length can span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.  ERR indicator This indicator flashes or lights up red if an error occurs. If the indicator does not turn off, please contact your Yamaha dealer.  LINK indicator This indicator flashes or lights up green, depending on the network status. Green (flashing) The unit is preparing to connect to the console network. If it continues flashing for a long time, the system is not functioning properly. If the problem persists after taking any of the following actions, please contact your Yamaha dealer. • Turn the power to the RIVAGE PM system off and then on. • Make sure that the cables are connected properly. • Make sure that the cables are securely inserted (locked in). • Change to a different cable. Green (lit The unit is connected to the console network steadily) properly.  TX/RX indicators The appropriate indicator flashes green when data is transmitted from (TX) or received at (RX) the CONSOLE NETWORK OUT/IN connectors. ? NETWORK connector This RJ-45 connector allows the unit to be connected to a computer via an Ethernet cable (CAT5 or higher recommended). This is used mainly for controlling mix parameters or editing scene memory and libraries from the dedicated "RIVAGE PM Editor" application program. NOTE • Use an STP (Shielded Twisted Pair) cable to prevent electromagnetic interference. Make sure that the metal parts of the plugs are electrically connected to the STP cable's shield by conductive tape or comparable means. • The use of Ethernet cables with Neutrik etherCON CAT5 compatible RJ-45 plugs is recommended. Standard RJ45 plugs can also be used. • Cable length can span up to 100 meters between devices. Maximum practical distance may vary depending on the cable used.  LINK/ACT indicator This indicator lights up or flashes green, depending on the connection status. When the indicator lights up, the link has been established. When the indicator flashes, data is being transmitted. HY card slots Enable you to install optional HY cards and connect to an I/O rack, such as RPio622, to expand I/O ports. HY card slot 1/2 can be used for a TWINLANe network card. HY card slot 3 is used for a generalpurpose I/O card. HY card slot 4 is used for a general purpose I/O card, as well as for virtual sound check (VSC). This unit supports the following HY cards. • Slot 1-2: HY256-TL, HY256-TL-SMF • Slot 1-4: HY144-D, HY144-D-SRC, HY128-MD For the latest information, refer to the Yamaha Pro Audio global website. http://www.yamahaproaudio.com/ DSP-RX(-EX) Owner's Manual 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

DSP-RX(-EX)
Owner’s Manual
11
8
WORD CLOCK OUT/IN connectors
These are BNC connectors used to transmit/receive
word clock signals to/from an external device. The
WORD CLOCK IN connector is internally
terminated by a 75 ohm resistor.
9
TC IN jack
This balanced XLR-3-31-type female jack accepts
time code signals from the connected external device.
)
NETWORK connector
This RJ-45 connector enables you to connect an
external device via an Ethernet cable (CAT5 or
higher).
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable’s shield by conductive tape or comparable means.
The use of Ethernet cables with Neutrik etherCON CAT5
compatible RJ-45 plugs is recommended. Standard
RJ45 plugs can also be used.
Cable length can span up to 100 meters between
devices. Maximum practical distance may vary
depending on the cable used.
!
LINK/ACT indicator
This indicator lights up or flashes green, depending
on the connection status.
When the indicator lights up, the link has been
established. When the indicator flashes, data is being
transmitted.
@
CONSOLE NETWORK OUT/IN connectors
These RJ-45 connectors allow this unit to be
connected to a control surface via Ethernet cables
(CAT5e or higher recommended).
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable’s shield by conductive tape or comparable means.
The use of Ethernet cables with Neutrik etherCON
CAT5e compatible RJ-45 plugs is recommended.
Standard RJ45 plugs can also be used.
Cable length can span up to 100 meters between
devices. Maximum practical distance may vary
depending on the cable used.
#
ERR indicator
This indicator flashes or lights up red if an error
occurs.
If the indicator does not turn off, please contact your
Yamaha dealer.
$
LINK indicator
This indicator flashes or lights up green, depending
on the network status.
%
TX/RX indicators
The appropriate indicator flashes green when data is
transmitted from (TX) or received at (RX) the
CONSOLE NETWORK OUT/IN connectors.
^
NETWORK
connector
This RJ-45 connector allows the unit to be connected
to a computer via an Ethernet cable (CAT5 or higher
recommended).
This is used mainly for controlling mix parameters or
editing scene memory and libraries from the
dedicated “RIVAGE PM Editor” application program.
NOTE
Use an STP (Shielded Twisted Pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable’s shield by conductive tape or comparable means.
The use of Ethernet cables with Neutrik etherCON CAT5
compatible RJ-45 plugs is recommended. Standard
RJ45 plugs can also be used.
Cable length can span up to 100 meters between
devices. Maximum practical distance may vary
depending on the cable used.
&
LINK/ACT indicator
This indicator lights up or flashes green, depending
on the connection status.
When the indicator lights up, the link has been
established. When the indicator flashes, data is being
transmitted.
*
HY card slots
Enable you to install optional HY cards and connect
to an I/O rack, such as RPio622, to expand I/O ports.
HY card slot 1/2 can be used for a TWINLANe
network card. HY card slot 3 is used for a general-
purpose I/O card. HY card slot 4 is used for a general
purpose I/O card, as well as for virtual sound check
(VSC).
This unit supports the following HY cards.
Slot 1-2: HY256-TL, HY256-TL-SMF
Slot 1-4: HY144-D, HY144-D-SRC, HY128-MD
For the latest information, refer to the Yamaha Pro
Audio global website.
Male XLR plug
1 (ground)
3 (Cold)
2 (Hot)
Green
(flashing)
The unit is preparing to connect to the console
network. If it continues flashing for a long time,
the system is not functioning properly.
If the problem persists after taking any of the
following actions, please contact your
Yamaha dealer.
Turn the power to the RIVAGE PM system
off and then on.
Make sure that the cables are connected
properly.
Make sure that the cables are securely
inserted (locked in).
Change to a different cable.
Green (lit
steadily)
The unit is connected to the console network
properly.