Yamaha MX49 Data List - Page 61

Address, Range, Parameter Name, Description, Default, Notes, High Mid Low, TOTAL SIZE = 62, 3E HEX

Page 61 highlights

MIDI Data Table Address Data Size Range High Mid Low (HEX) Parameter Name Description 37 pp 00 1 01 1 02 1 03 1 04 1 05 1 06 1 07 1 08 1 09 1 0A 1 0B 1 0C 1 0D 1 0E 1 0F 1 10 2 12 1 13 1 14 1 15 1 reserved 00 - 7F Bank Select MSB 00 - 7F Bank Select LSB 00 - 7F Program Number 00 - 0F, Receive Channel 7F 00 - 01 Mono/Poly 01 - 7F Velocity Limit Low 01 - 7F Velocity Limit High 00 - 7F Note Limit Low 00 - 7F Note Limit High 10 - 4C Pitch Bend Range Upper 10 - 4C Pitch Bend Range Lower 00 - 7F Velocity Sensitivity Depth 00 - 7F Velocity Sensitivity Offset 00 - 7F Volume 01 - 7F Pan 00 - 0F Detune 00 - 0F 00 - 7F 00 - 7F 00 - 7F Reverb Send Chorus Send reserved Dry Level 0 - 127 0 - 127 1 - 128 1..16, off (7F) mono, poly 1 - 127 1 - 127 C-2 - G8 C-2 - G8 -48 - +12 -48 - +12 0 - 127 0 - 127 0 - 127 L63 - C - R63 -12.8 - +12.7 [Hz] 1st bit 3-0  bit 7-4, 2nd bit 3-0  bit 3-0 0 - 127 0 - 127 0 - 127 16 1 28 - 58 Note Shift 17 1 reserved 18 1 00 - 01 Param. with Voice 19 1 reserved 1A 1 00 - 01 Portamento Switch 1B 1 00 - 7F Portamento Time 1C 1 00 - 01 Portamento Mode 1D 1 reserved -24 - +24 [semitones] off, on off, on 0 - 127 fingered, fulltime 1E 1 reserved 37 pp 1F 1 18 - 7C Receive PB bit 6: off, on PB Receive AT bit 5: off, on AT Receive Program Change bit 4: off, on Program Change Receive Bank Select bit 3: off, on Bank Select Receive Control Change bit 2: off, on Control Change reserved bit 1-0: reserved 20 1 02 - 6F Receive FC2 bit 6: off, on FC2 Receive FC1 bit 5: off, on FC1 reserved bit 4: reserved Receive MW bit 3: off, on MW Receive Sustain/Sostenuto bit 2: off, on Sustain/ Sostenuto Receive Pan bit 1: off, on Pan Receive Volume/Expression bit 0: off, on Volume/ Expression 21 1 00 - 7F Receive Assignable Switch bit 6: off, on ASW2 2 Receive Assignable Switch bit 5: off, on ASW1 1 Receive Assignable Knob 2 bit 4: off, on AKN2 Receive Assignable Knob 1 bit 3: off, on AKN1 Receive RB bit 2: off, on RB Receive BC bit 1: off, on BC Receive FS bit 0: off, on FS 37 pp 22 1 00 - 01 Voice Element Pan off, on 23 1 00 - 7F AEG Attack Time -64 - +63 24 1 00 - 7F AEG Decay Time -64 - +63 25 1 00 - 7F AEG Sustain Level -64 - +63 26 1 00 - 7F AEG Release Time -64 - +63 27 1 00 - 7F FEG Attack Time -64 - +63 28 1 00 - 7F FEG Decay Time -64 - +63 29 1 00 - 7F FEG Sustain Level -64 - +63 2A 1 00 - 7F FEG Release Time -64 - +63 2B 1 00 - 7F FEG Depth -64 - +63 2C 1 reserved 2D 1 00 - 7F Filter Cutoff Frequency 2E 1 00 - 7F Filter Resonance 37 pp 2F 1 reserved 30 1 reserved 31 1 reserved 32 1 reserved 33 1 reserved 34 1 reserved 35 1 reserved -64 - +63 -64 - +63 Default (HEX) Notes 3F 00 00 Part No. 01 01 7F 00 7F 42 3E 40 40 64 40 08 00 (80) 0C 00 7F 40 01 00 40 01 7C 6F 7F 01 40 40 40 Only for Normal Voice 40 Only for Normal Voice 40 Only for Normal Voice 40 Only for Normal Voice 40 Only for Normal Voice 40 Only for Normal Voice 40 Only for Normal Voice 40 40 Address Data Size Range High Mid Low (HEX) Parameter Name 36 1 reserved 37 1 reserved 38 1 reserved 39 1 reserved 3A 1 reserved 3B 1 reserved 37 pp 3C 1 00 - 7F Assignable Knob 1 Value 3D 1 00 - 7F Assignable Knob 2 Value TOTAL SIZE = 62 3E (HEX) pp = part number 00 - 0F Description -64 - +63 -64 - +63 Default (HEX) Notes 40 40 Address Data Size Range High Mid Low (HEX) Parameter Name Description Default (HEX) Notes 38 pp 00 1 00 - 01 ARP Switch off, on 00 01 1 00 - 01 ARP MIDI Out Switch off, on 00 02 1 00 - 0F ARP Transmit Channel 1..16 Part No. 03 1 00 - 01 ARP Play Only off, on 00 Determines whether or not the current Part plays only the note events of the Arpeggio playback 04 1 reserved 05 1 reserved 06 1 00 - 01 ARP Loop off, on 01 07 1 00 - 02 ARP Hold sync-off, off, on 01 08 1 00 - 06 ARP Unit Multiply 50%, 66%, 75%, 03 100%, 133%, 150%, 200% 09 1 00 - 7F ARP Note Limit Low C-2..G8 00 0A 1 00 - 7F ARP Note Limit High C-2..G8 7F 0B 1 01 - 7F ARP Velocity Limit Low 1 - 127 01 0C 1 01 - 7F ARP Velocity Limit High 1 - 127 7F 0D 1 00 - 04 ARP Key Mode sort, thru, direct, 00 sort+direct, thru+direct 0E 1 00 - 01 ARP Velocity Mode original, thru 00 0F 1 00 - 01 ARP Change Timing realtime, measure 01 10 1 01 - 07 ARP Quantize Value 32th, 16th_Triplet, 03 16th, 8th_Triplet, 8th, 4th_Triplet, 4th 11 1 00 - 64 ARP Quantize Strength 0...100% 00 12 2 00 - 01 ARP Velocity Rate 00 - 48 0...200% 00 64 14 2 00 - 01 ARP Gate Time Rate 0...200% 00 00 - 48 64 16 1 reserved 17 1 reserved 18 1 reserved 19 1 reserved 1A 2 00 - 01 ARP Swing 08 - 78 -120 ... 0 ... +120 01 00 1C 1 00 - 7F ARP Accent Velocity off, 1 ... 127 40 Threshold 1D 1 00 - 01 ARP Accent Start off, on 01 Quantize 1E 1 3D - 43 ARP Octave Range -3 ... 0 ... +3 40 1F 1 36 - 4A ARP Output Octave Shift -10 ... 0 ... +10 40 20 1 00 - 01 ARP Trigger Mode gate, toggle 00 21 1 00 - 01 ARP Random SFX off, on 01 22 1 00 - 01 ARP Random SFX Key off, on 01 On Control 23 1 00 - 7F ARP Random SFX -64 ... 0 ... +63 40 Velocity Offset 24 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF1 00 26 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF1 00 28 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF2 00 2A 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF2 00 2C 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF3 00 2E 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF3 00 30 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF4 00 32 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF4 00 34 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF5 00 36 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF5 00 38 2 00 - 01 ARP Assign Velocity -100 ... 0 ... +100 01 1C - 64 Rate Offset SF6 00 3A 2 00 - 01 ARP Assign Gate Time -100 ... 0 ... +100 01 1C - 64 Offset SF6 00 61 MX49/MX61 Data List

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

MX49/MX61 Data List
61
MIDI Data Table
TOTAL SIZE = 62
3E (HEX)
pp = part number
00 – 0F
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low
37
pp
00
1
reserved
01
1
00 – 7F
Bank Select MSB
0 – 127
3F
02
1
00 – 7F
Bank Select LSB
0 – 127
00
03
1
00 – 7F
Program Number
1 – 128
00
04
1
00 – 0F,
7F
Receive Channel
1..16, off (7F)
Part
No.
05
1
00 – 01
Mono/Poly
mono, poly
01
06
1
01 – 7F
Velocity Limit Low
1 – 127
01
07
1
01 – 7F
Velocity Limit High
1 – 127
7F
08
1
00 – 7F
Note Limit Low
C-2 – G8
00
09
1
00 – 7F
Note Limit High
C-2 – G8
7F
0A
1
10 – 4C
Pitch Bend Range Upper
-48 – +12
42
0B
1
10 – 4C
Pitch Bend Range Lower
-48 – +12
3E
0C
1
00 – 7F
Velocity Sensitivity Depth
0 – 127
40
0D
1
00 – 7F
Velocity Sensitivity Offset
0 – 127
40
0E
1
00 – 7F
Volume
0 – 127
64
0F
1
01 – 7F
Pan
L63 – C – R63
40
10
2
00 – 0F
00 – 0F
Detune
-12.8 – +12.7 [Hz]
1st bit 3-0
bit 7-4,
2nd bit 3-0
bit 3-0
08
00
(80)
12
1
00 – 7F
Reverb Send
0 – 127
0C
13
1
00 – 7F
Chorus Send
0 – 127
00
14
1
reserved
15
1
00 – 7F
Dry Level
0 – 127
7F
16
1
28 – 58
Note Shift
-24 – +24 [semitones]
40
17
1
reserved
18
1
00 – 01
Param. with Voice
off, on
01
19
1
reserved
1A
1
00 – 01
Portamento Switch
off, on
00
1B
1
00 – 7F
Portamento Time
0 – 127
40
1C
1
00 – 01
Portamento Mode
fingered, fulltime
01
1D
1
reserved
1E
1
reserved
37
pp
1F
1
18 – 7C
Receive PB
Receive AT
Receive Program Change
Receive Bank Select
Receive Control Change
reserved
bit 6: off, on PB
bit 5: off, on AT
bit 4: off, on Program
Change
bit 3: off, on Bank Select
bit 2: off, on Control
Change
bit 1-0: reserved
7C
20
1
02 – 6F
Receive FC2
Receive FC1
reserved
Receive MW
Receive Sustain/Sostenuto
Receive Pan
Receive Volume/Expression
bit 6: off, on FC2
bit 5: off, on FC1
bit 4: reserved
bit 3: off, on MW
bit 2: off, on Sustain/
Sostenuto
bit 1: off, on Pan
bit 0: off, on Volume/
Expression
6F
21
1
00 – 7F
Receive Assignable Switch
2
Receive Assignable Switch
1
Receive Assignable Knob 2
Receive Assignable Knob 1
Receive RB
Receive BC
Receive FS
bit 6: off, on ASW2
bit 5: off, on ASW1
bit 4: off, on AKN2
bit 3: off, on AKN1
bit 2: off, on RB
bit 1: off, on BC
bit 0: off, on FS
7F
37
pp
22
1
00 – 01
Voice Element Pan
off, on
01
23
1
00 – 7F
AEG Attack Time
-64 – +63
40
24
1
00 – 7F
AEG Decay Time
-64 – +63
40
25
1
00 – 7F
AEG Sustain Level
-64 – +63
40
Only for
Normal
Voice
26
1
00 – 7F
AEG Release Time
-64 – +63
40
Only for
Normal
Voice
27
1
00 – 7F
FEG Attack Time
-64 – +63
40
Only for
Normal
Voice
28
1
00 – 7F
FEG Decay Time
-64 – +63
40
Only for
Normal
Voice
29
1
00 – 7F
FEG Sustain Level
-64 – +63
40
Only for
Normal
Voice
2A
1
00 – 7F
FEG Release Time
-64 – +63
40
Only for
Normal
Voice
2B
1
00 – 7F
FEG Depth
-64 – +63
40
Only for
Normal
Voice
2C
1
reserved
2D
1
00 – 7F
Filter Cutoff Frequency
-64 – +63
40
2E
1
00 – 7F
Filter Resonance
-64 – +63
40
37
pp
2F
1
reserved
30
1
reserved
31
1
reserved
32
1
reserved
33
1
reserved
34
1
reserved
35
1
reserved
36
1
reserved
37
1
reserved
38
1
reserved
39
1
reserved
3A
1
reserved
3B
1
reserved
37
pp
3C
1
00 – 7F
Assignable Knob 1 Value
-64 – +63
40
3D
1
00 – 7F
Assignable Knob 2 Value
-64 – +63
40
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low
38
pp
00
1
00 – 01
ARP Switch
off, on
00
01
1
00 – 01
ARP MIDI Out Switch
off, on
00
02
1
00 – 0F
ARP Transmit Channel
1..16
Part No.
03
1
00 – 01
ARP Play Only
off, on
00
Determines
whether or not
the current Part
plays only the
note events of
the Arpeggio
playback
04
1
reserved
05
1
reserved
06
1
00 – 01
ARP Loop
off, on
01
07
1
00 – 02
ARP Hold
sync-off, off, on
01
08
1
00 – 06
ARP Unit Multiply
50%, 66%, 75%,
100%, 133%, 150%,
200%
03
09
1
00 – 7F
ARP Note Limit Low
C-2..G8
00
0A
1
00 – 7F
ARP Note Limit High
C-2..G8
7F
0B
1
01 – 7F
ARP Velocity Limit Low
1 – 127
01
0C
1
01 – 7F
ARP Velocity Limit High
1 – 127
7F
0D
1
00 – 04
ARP Key Mode
sort, thru, direct,
sort+direct,
thru+direct
00
0E
1
00 – 01
ARP Velocity Mode
original, thru
00
0F
1
00 – 01
ARP Change Timing
realtime, measure
01
10
1
01 – 07
ARP Quantize Value
32th, 16th_Triplet,
16th, 8th_Triplet, 8th,
4th_Triplet, 4th
03
11
1
00 – 64
ARP Quantize Strength
0...100%
00
12
2
00 – 01
00 – 48
ARP Velocity Rate
0...200%
00 64
14
2
00 – 01
00 – 48
ARP Gate Time Rate
0...200%
00
64
16
1
reserved
17
1
reserved
18
1
reserved
19
1
reserved
1A
2
00 – 01
08 – 78
ARP Swing
-120 … 0 … +120
01
00
1C
1
00 – 7F
ARP Accent Velocity
Threshold
off, 1 … 127
40
1D
1
00 – 01
ARP Accent Start
Quantize
off, on
01
1E
1
3D – 43
ARP Octave Range
-3 … 0 … +3
40
1F
1
36 – 4A
ARP Output Octave Shift
-10 … 0 … +10
40
20
1
00 – 01
ARP Trigger Mode
gate, toggle
00
21
1
00 – 01
ARP Random SFX
off, on
01
22
1
00 – 01
ARP Random SFX Key
On Control
off, on
01
23
1
00 – 7F
ARP Random SFX
Velocity Offset
-64 … 0 … +63
40
24
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF1
-100 … 0 … +100
01
00
26
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF1
-100 … 0 … +100
01
00
28
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF2
-100 … 0 … +100
01
00
2A
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF2
-100 … 0 … +100
01
00
2C
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF3
-100 … 0 … +100
01
00
2E
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF3
-100 … 0 … +100
01
00
30
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF4
-100 … 0 … +100
01
00
32
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF4
-100 … 0 … +100
01
00
34
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF5
-100 … 0 … +100
01
00
36
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF5
-100 … 0 … +100
01
00
38
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF6
-100 … 0 … +100
01
00
3A
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF6
-100 … 0 … +100
01
00
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low