Yamaha P-85 Data List - Page 4

XG Native Bulk Data reception only - p 85 digital piano by

Page 4 highlights

8. SYSTEM EXCLUSIVE MESSAGES (XG Standard) (1) XG Native Parameter Change Data format: [F0H] -> [43H] -> [1nH] -> [4CH] -> [hhH] -> [mmH] -> [llH] -> [ddH] -> [F7H] F0H = Exclusive status 43H = YAMAHA ID 1nH = When received, n=0-F. When transmitted, n=0. 4CH = Model ID of XG hhH = Address High mmH = Address Mid llH = Address Low ddH = Data | F7H = End of Exclusive Data size must match parameter size (2 or 4 bytes). When the XG System On message is received, the MIDI system will be reset to its default settings. The message requires approximately 50ms to execute, so sufficient time should be allowed before the next message is sent. (2) XG Native Bulk Data (reception only) Data format: [F0H] -> [43H] -> [0nH] -> [4CH] -> [aaH] -> [bbH] -> [hhH] -> [mmH] -> [llH] -> [ddH] ->...-> [ccH] -> [F7H] F0H = Exclusive status 43H = YAMAHA ID 0nH = When received, n=0-F. When transmitted, n=0. 4CH = Model ID of XG aaH = ByteCount bbH = ByteCount hhH = Address High mmH = Address Mid llH = Address Low ddH = Data | | | | ccH = Check sum F7H = End of Exclusive • Receipt of the XG SYSTEM ON message causes reinitialization of relevant parameters and Control Change values. Allow sufficient time for processing to execute (about 50 msec) before sending the P-85 another message. • XG Native Parameter Change message may contain two or four bytes of parameter data (depending on the parameter size). • For information about the Address and Byte Count values, refer to Table 1 below. Note that the table's Total Size value gives the size of a bulk block. Only the top address of the block (00H, 00H, 00H) is valid as a bulk data address. 9. SYSTEM EXCLUSIVE MESSAGES (Digital Piano MIDI Format) Data format: [F0H] -> [43H] -> [73H] -> [01H] -> [xxH] -> [F7H] F0H = Exclusive status 43H = Yamaha ID 73H = Digital Piano ID 01H = Product ID (digital piano common) xxH = Substatus nn Control 02H Internal MIDI clock 03H External MIDI clock 06H Bulk Data (the bulk data follows 06H) F7H = End of Exclusive 10. SYSTEM EXCLUSIVE MESSAGES (Special Control) Data format: [F0H] -> [43H] -> [73H] -> [xxH] -> [11H] -> [0nH] -> [ccH] -> [vvH] -> [F7H] F0H = Exclusive status 43H = Yamaha ID 73H = Digital Piano ID 7FH = Extended Product ID 4BH = Product ID 11H = Special control 0nH = Control MIDI change (n=channel number) ccH = Control number vvH = Value F7H = End of Exclusive Control Channel ccH vvH Channel Detune ch: 00H-0FH 43H (Sets the Detune value for each channel) 00H-7FH Voice Reserve ch: 00H-0FH 45H 00H : Reserve off 7FH: on* * When Volume, Expression is received for Reserve On, they will be effective from the next Key On. Reserve Off is normal. 11. SYSTEM EXCLUSIVE MESSAGES (Others) Data format: [F0H] -> [43H] -> [1nH] -> [27H] -> [30H] -> [00H] -> [00H] -> [mmH] -> [llH] -> [ccH] -> [F7H] Master Tuning (XG and last message priority) simultaneously changes the pitch of all channels. F0H = Exclusive Status 43H = Yamaha ID 1nH = When received, n=0-F. When transmitted, n=0. 27H = Model ID of TG100 30H = Sub ID 00H = 00H = mmH = Master Tune MSB llH = Master Tune LSB ccH = irrelevant (under 7FH) F7H = End of Exclusive [4] P-85 Data List

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

8. SYSTEM EXCLUSIVE MESSAGES (XG Standard)
10. SYSTEM EXCLUSIVE MESSAGES (Special Control)
Data format:
(1) XG Native Parameter Change
Data format:
F0H = Exclusive status
43H =
Yamaha ID
F0H = Exclusive status
73H =
Digital Piano ID
43H =
YAMAHA ID
7FH = Extended Product ID
1nH =
When received, n=0–F.
4BH = Product ID
When transmitted, n=0.
11H =
Special control
4CH = Model ID of XG
0nH =
Control MIDI change (n=channel number)
hhH =
Address High
ccH =
Control number
mm
H = Address Mid
vvH =
Value
llH =
Address Low
F7H = End of Exclusive
ddH =
Data
|
Control
Channel
ccH
vvH
F7H = End of Exclusive
Channel Detune
ch: 00H–0FH 43H (Sets the Detune value
for each channel)
00H–7FH
Voice Reserve
ch: 00H–0FH 45H
00H : Reserve off
7FH: on*
*
(2) XG Native Bulk Data (reception only)
11. SYSTEM EXCLUSIVE MESSAGES (Others)
Data format:
Data format:
F0H = Exclusive status
43H =
YAMAHA ID
0nH =
When received, n=0–F.
When transmitted, n=0.
F0H = Exclusive Status
4CH = Model ID of XG
43H =
Yamaha ID
aaH =
ByteCount
1nH =
When received, n=0–F.
bbH =
ByteCount
When transmitted, n=0.
hhH =
Address High
27H =
Model ID of TG100
mm
H = Address Mid
30H =
Sub ID
llH =
Address Low
00H =
ddH =
Data
00H =
|
|
mm
H = Master Tune MSB
|
|
llH =
Master Tune LSB
ccH =
Check sum
ccH =
irrelevant (under 7FH)
F7H = End of Exclusive
F7H = End of Exclusive
9. SYSTEM EXCLUSIVE MESSAGES
(Digital Piano MIDI Format)
Data format:
[F0H] -> [43H] -> [73H] -> [01H] -> [xxH] -> [F7H]
F0H = Exclusive status
43H =
Yamaha ID
73H =
Digital Piano ID
01H =
Product ID (digital piano common)
xxH =
Substatus
nn
Control
02H
Internal MIDI clock
03H
External MIDI clock
06H
Bulk Data (the bulk data follows 06H)
F7H = End of Exclusive
For information about the Address and Byte Count values,
refer to Table 1 below. Note that the table’s Total Size value
gives the size of a bulk block. Only the top address of the
block (00H, 00H, 00H) is valid as a bulk data address.
When Volume, Expression is received for Reserve On,
they will be effective from the next Key On. Reserve Off is
normal.
Master Tuning (XG and last message priority)
simultaneously changes the pitch of all channels.
[F0H] -> [43H] -> [1nH] -> [4CH] -> [hhH] ->
[
mm
H] -> [llH] -> [ddH] -> [F7H]
Receipt of the XG SYSTEM ON message causes
reinitialization of relevant parameters and Control Change
values. Allow sufficient time for processing to execute
(about 50 msec) before sending the P-85 another message.
When the XG System On message is received, the MIDI
system will be reset to its default settings.
The message requires approximately 50ms to execute, so
sufficient time should be allowed before the next message
is sent.
XG Native Parameter Change message may contain two or
four bytes of parameter data (depending on the parameter
size).
[F0H] -> [43H] -> [1nH] -> [27H] -> [30H] ->
[00H] -> [00H] -> [
mm
H] -> [llH] -> [ccH] -> [F7H]
Data size must match parameter size (2 or 4 bytes).
[F0H] -> [43H] -> [0nH] -> [4CH] -> [aaH] ->
[bbH] -> [hhH] ->
[mm
H] -> [llH] -> [ddH] ->...->
[ccH] -> [F7H]
[F0H] -> [43H] -> [73H] -> [xxH] -> [11H] ->
[0nH] -> [ccH] -> [vvH] -> [F7H]
[4] P-85 Data List