Yamaha RM1x List Book - Page 16
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 01H F7H - midi cc messages
View all Yamaha RM1x manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
SOUND CONTROLLER 6 adjusts the envelope decay time specified by the Voice. This is a relative parameter, and specifies an increase or decrease centered at 64. BRIGHTNESS adjusts the cutoff frequency specified by the Voice. This is a relative parameter, and specifies an increase or decrease centered at 64. Decreasing the value will make the sound more mellow. For some voices, the effective range may be less than the range of the setting. SOUND CONTROLLER 7 adjusts the LFO Frequency specified by the Voice. This is a relative parameter, and specifies an increase or decrease centered at 64. (3-2) CHANNEL MODE MESSAGES STATUS CONTROL NUMBER CONTROL VALUE 1011nnnn(BnH) 0ccccccc 0vvvvvvv n = 0 ~ 15 VOICE CHANNEL NUMBER c = CONTROL NUMBER v = DATA VALUE (3-2-1) ALL SOUND OFF (CONTROL NUMBER = 78H , DATA VALUE = 0) Turns off the sound of all currently sounding notes on the corresponding channel. The status of channel messages such as Note On and Hold On is also turned off. (3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H , DATA VALUE = 0) Resets the values of the following controllers. PITCH BEND CHANGE 0 (center) MODULATION 0 (off) AC1 CONTROLLER 0 (minimum) EXPRESSION 127 (maximum) SUSTAIN SWITCH 0 (off) PORTAMENTO SWITCH 0 (off) SOSTENUTO SWITCH 0 (off) SOFT PEDAL 0 (off) NRPN Un-set status. Internal data will not change. RPN Un-set status. Internal data will not change. PORTAMENT CONTROL reset The following data will not change. PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN, HARMONIC CONTENT, RELEASE TIME, ATTACK TIME, BRIGHTNESS, SOUND CONTROLLER 6,SOUND CONTROLLER 7, DRY SEND LEVEL,EFFECT SEND LEVEL 1, EFFECT SEND LEVEL 3,EFFECT SEND LEVEL 4,PITCH BEND SENSITIBITY, FINE TUNING, COURSE TUNING (3-2-3) ALL NOTE OFF (CONTROL NUMBER = 7BH , DATA VALUE = 0) Turns off all notes of the corresponding channel which are on. However if Sustain or Sostenuto are on, the sound will continue until these are turned off. (3-2-4) OMNI MODE OFF (CONTROL NUMBER = 7CH , DATA VALUE = 0) Performs the same processing as when ALL NOTE OFF is received. Sets the VOICE RECEIVE CHANNEL to OMNI OFF and CHANNEL = 1. (3-2-5) OMNI MODE ON (CONTROL NUMBER = 7DH , DATA VALUE = 0) Performs the same processing as when ALL NOTE OFF is received. Does not set OMNI ON. Sets the VOICE RECEIVE CHANNEL to OMNI ON. (3-2-6) MONO (CONTROL NUMBER = 7EH , DATA VALUE = 0) Performs the same processing as when All SOUND OFF is received, and if the 3rd byte (mono number) is in the range 0 - 16, sets the corresponding channel to Mode 4 (m=1). If in the VOICE MODE, Mode 2 (m=1) is also possible, according to the VOICE RECEIVE CHANNEL. (3-2-7) POLY (CONTROL NUMBER = 7FH , DATA VALUE = 0) Performs the same processing as when ALL SOUND OFF is received, and sets the corresponding channel to Mode 3. When in the VOICE MODE, Mode 1 is also possible, according to the VOICE RECEIVE CHANNEL. (3-3) REGISTERED PARAMETER NUMBER STATUS LSB RPN LSB MSB RPN MSB DATA ENTRY MSB DATA VALUE DATA ENTRY LSB DATA VALUE 1011nnnn(BnH) 01100100(64H) 0ppppppp 01100101(65H) 0qqqqqqq 00000110(06H) 0mmmmmmm 00100110(26H) 0lllllll n = 0 - 15 VOICE CHANNEL NUMBER p = RPN LSB (Refer to the table on the following page.) q = RPN MSB (Refer to the table on the following page.) m = Data Value l = Data Value First transmit an RPN MSB and RPN LSB to specify the parameter that is to be controlled, then use Data Entry to set the value of the specified parameter. RPN D.ENTRY LSB MSB MSB LSB PARAMETER NAME DATA RANGE 00H 00H mmH --01H 00H mmH llH 02H 00H mmH --7FH 7FH --- --- PITCH BEND SENSITIVITY MASTER FINE TUNE MASTER COARSE TUNE RPN RESET 00H - 18H (0 - 24 semitones) {mmH,llH} = {00H,00H} - {40H,00H} - {7FH,7FH} (-8192*100/8192) - 0 - (+8192*100/8192) 28H - 40H - 58H (-24 - 0 - +24 semitones) Set to a condition in which the RPN number is unspecified. Internal settings will not change. (3-4) NON-REGISTERED PARAMETER NUMBER STATUS 1011nnnn(BnH) LSB 01100010(62H) RPN LSB 0ppppppp MSB 01100011(63H) RPN MSB 0qqqqqqq DATA ENTRY MSB 00000110(06H) DATA VALUE 0mmmmmmm n = 0 - 15 VOICE CHANNEL NUMBER p = NRPN LSB (Refer to the table on the following page.) q = NRPN MSB (Refer to the table on the following page.) m = Data Value First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be controlled, then use Data Entry to set the value of the specified parameter. NRPN MSB LSB 01H 08H 01H 09H 01H 0AH 01H 20H 01H 21H 01H 63H 01H 64H 01H 66H MSB LSB mmH --mmH --mmH --mmH --mmH --mmH --mmH --mmH --- D.ENTRY PARAMETER NAME DATA RANGE VIBRATO RATE VIBRATO DEPTH VIBRATO DELAY FILTER CUTOFF FREQUENCY FILTER RESONANCE EG ATTACK TIME EG DECAY TIME EG RELEASE TIME 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) 00H - 40H - 7FH (-64 - 0 - +63) (3-5) SYSTEM REAL TIME MESSAGES (3-5-1) ACTIVE SENSING STATUS 11111110 (FEH) Transmitted at intervals of approximately 200 msec. Not transmitted during disk read/write operations. Once this message is received, SENSING will begin. If neither STATUS nor DATA messages are received for an interval longer than approximately 350 msec, the MIDI RECEIVE BUFFER will be cleared, and all sounding notes and SUSTAIN SWITCH will be forced off. Also, data for each of the controls will be reset to specific values. (3-6) SYSTEM EXCLUSIVE MESSAGE (3-6-1)UNIVERSAL NON REALTIME MESSAGE (3-6-1-1)GENERAL MIDI MODE ON F0H 7EH 7FH 09H 01H F7H The following controller values will be reset. VOLUME PAN PROGRAM CHANGE BANK SELECT MSB REVERB DEPTH PITCH BEND CHANGE MODULATION EXPRESSION SUSTAIN SWITCH SOSTENUTO SWITCH RPN PORTAMENT CONTROL MIDI MASTER VOLUME PITCH BEND SENSITIBITY FINE TUNING COURSE TUNING 100 Center 1 (Grandpno) 0 4 0 (center) 0 (off) 127 (maximum) 0 (off) 0 (off) Un-set status. reset 127 (maximum) 02 (2 semitones) 0 0 (3-6-1-2)IDENTITY REQUEST (Received only) F0H 7EH 0nH 06H 01H F7H ("n" is the device number, but the RM1x receives this in Omni.) (3-6-1-3)IDENTITY REPLY (Transmitted only) F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 01H F7H dd;Device Number Code RM1x = 1DH,03H (3-6-2)UNIVERSAL REALTIME MESSAGE (3-6-2-1) MIDI MASTER VOLUME F0H 7FH 7FH 04H 01H llH mmH F7H Modifies the MASTER VOLUME value. The value of mm is used as the MIDI Master Volume (the ll value is ignored). (3-6-3)PARAMETER CHANGE (3-6-3-1) MIDI MASTER TUNING F0H 43H 1nH 27H 30H 00H 00H mmH llH ccH F7H Modifies the MASTER TUNE value. The values of mm and ll are used as the MIDI Master Tuning.(n and cc values are ignored.) T = M*200/256-100 Where T : actual tuning value (-99 - +99) M: a one-byte value with MSB of "mm" bits 0-3, and LSB of "ll" bits 0-3. (3-6-3-2) XG SYSTEM ON 11110000 F0 01000011 43 0001nnnn 1n 01001100 4C 0aaaaaaa 00 0aaaaaaa 00 0aaaaaaa 7E 00000000 00 11110111 F7 Exclusive status YAMAHA ID device Number Model ID Address High Address Mid Address Low Data End of Exclusive When ON is received, controllers will be reset and all Multi Part and Effect data of the attached table will be reset to the XG default values. (3-6-3-3) XG PARMETER CHANGE 11110000 01000011 0001nnnn 01001100 0aaaaaaa 0aaaaaaa 0aaaaaaa 0ddddddd | 11110111 F0 43 1n 4C aaaaaaa aaaaaaa aaaaaaa ddddddd F7 Exclusive status YAMAHA ID device Number Model ID Address High Address Mid Address Low Data | End of Exclusive For parameters with a Data Size of 2 or 4, the corresponding amount of data will be transmitted. For Addresses and Byte Counts, refer to the attached tables. The following 3 types are received. System Data Multi Effect Data Multi Part Data 16