Yamaha V1.6 PX10/PX8/PX5/PX3 V1.6 Reference Manual [English] - Page 37
LOG, Initializing the PX amplifier, To initialize the current parameters
View all Yamaha V1.6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
LOG (Advanced mode only) Indicates or saves the operation log in the PX amplifier. q w Panel Operation - Initializing the PX amplifier Initializing the PX amplifier There are three ways to initialize the PX amplifier. To initialize the current parameters 1. Turn on while pressing the [A] key. q LOG LIST Indicates the overall operation log stored in the PX amplifier. The log is displayed in the order that events have occurred. The time information is displayed in "NNNN HHH:MM:SS" format, where the format represents the number of hours (HHH)/minutes (MM)/seconds (SS) have elapsed since the (NNNN)th power-on. • Operation log indication 2. Rotate the main knob to select "CONFIG+TUNING" and press the main knob. Rotating the main knob (to select an event) and pressing the knob (to actually determine the event) show the detailed view. NOTE The Operation log can also be called up by selecting and determining the [ the main knob when the [ ] icon is shown in the HOME screen. ] icon by using w SAVE TO USB Save the latest operation log to a USB flash drive. The function is for user support reference. NOTE Current parameters are parameters set in the CONFIG WIZARD, AMP PRESET, and TUNING screens. For details, refer to "Function list" (page 39). PX10/PX8/PX5/PX3 Reference Manual 37