Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
A AE00241 GROUND (Earth) Make sure to ground (earth) the generator. Check "SAFETY INFORMATION" on page 7. å EF4000DE/YG4000D 741-061 ∫ EF5200DE/EF6600DE/YG5200D/YG6600D/YG6600DE B w e q 741-066 830-002a q 762-004 AE00231 BATTERY (for EF4000DE/EF5200DE/EF6600DE/YG6600DE) (See page 34 for more details) Check the fluid level and fill if necessary. Use only distilled water if refilling is necessary. Installation 1. Turn the engine switch to the "STOP" position to prevent accidental short circuiting. 2. Install the battery on the battery mount tray securely. NOTE: Clamp the red wire to the positive (+) terminal first, then the black wire to the negative (-) terminal of the battery. Do not reverse these positions. w Be sure to service battery leads to prevent arcing when the battery is not installed. 9 Disconnect the battery charging output lead. Then insulate the generator side connector by 762-005 folding it back on itself and carefully wraping it with electrical tape to prevent electrical con- tact with ground (earth) or any other leads. 9 Remove the battery leads from the generator. 1 Connector 2 Battery leads 3 Electrical tape - 18 -