Zenith SL-4144-NB User Guide - Page 3
Wiring - a
UPC - 016963414419
View all Zenith SL-4144-NB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
4. Rotate the mounting plate so the wire path is on the upper right. Note: The wire path on the mounting plate must be located as shown below to allow the wires on the back of the fixture to pass through. 5. Reinstall the fixture mounting screws and attach the mounting plate to the junction box as shown. Wire Path Ground Screw Wire Path Fixture Screws As Shipped Flipped and Rotated White Black Green or Bare Light Fixture Light Fixture Two Motion Lights ❒ Twist the junction box wires and the fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green "pigtail". If you are unsure about the grounding method, consult your local building code. Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors. WIRING Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system. Recommended Grounding Method Use a green ground "pigtail" (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the "pigtail" with the GND screw on the mounting plate. CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor. Black Green or Bare White One Motion Light Light Fixture 595-5578-09 Black to black White to white