Zenith SL-6168-D User Guide - Page 6
Jumpers in positions 1 through 7 must be exactly the same for both, the sensor and chime for
UPC - 016963616806
View all Zenith SL-6168-D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
4. To change the code, either: • Add a jumper to the same location on both the sensor and the chime or... • Remove a jumper from the same location on both the sensor and the chime or... • Move a jumper on the sensor from one location to another. Move the corresponding jumper on the chime to match the new location in the sensor. Example: Move jumper at location "5" to location "4" on both the sensor and the chime. Note: Jumpers in positions 1 through 7 must be exactly the same for both the sensor and chime for this system to function. Note: Unit will come factory set with jumpers in locations 5, 6, and 7 on the sensor and on the chime. The range of the wireless chime can vary with location, temperature, and battery condition. * Code Settings 1-7 Must Match Both Sensor and Chime 12345678 12345678 Inside Sensor Remove screw to open access door Back of Chime Note: Some models might require the use of tweezers to remove and replace the jumpers. HeathCo LLC reserves the right to discontinue and to change specifications at any time without notice without incurring any obligation to incorporate new features in previously sold products. -- 595-5724-04