ZyXEL HLA3105 User Guide - Page 2

Product Specifications, Wall Mounting, Safety Warnings - communications

Page 2 highlights

HLA3105 USER'S GUIDE Product Specifications Dimensions 112 mm (W) x 106 mm (D) x 28.5 mm (H) Device Weight 167 g Two Coaxial Connectors IN: connect to a coaxial outlet in the home OUT: connect to a TV or set-top box One RJ-45 Ethernet Port Auto-negotiating: 10 Mbps or 100 Mbps in either half-duplex or full-duplex mode. Auto-crossover: Use either crossover or straight-through Ethernet cables. Power Input: 100 - 240 VAC 50/60 Hz Specification Output: 5V 1A DC Operating Environment Temperature: 0 ºC ~ 40 ºC Humidity: 20%~ 85% RH (noncondensing) Storage Environment Temperature: -30 ºC ~ 60 ºC Humidity: 20%~ 95% RH (noncondensing) Certifications HomePNA Safety • CSA C22.2 No.60950-1 • UL 60950-1 • EN 60950-1 • IEC 60950-1 EMC • European Union (CE mark): EN55022 Class B (1998) • North America: FCC Part 15 (Class B) Distance between wallmounting holes on device's base panel 75.8 mm Screw size for M4 Tap wall mounting 12/2010 Version 1.9.5, Edition 1 Copyright 2010 ZyXEL Communications Corp. Wall Mounting It is recommended that you do NOT wall-mount the HLA3105. Wall-mounting kit is not included. Complete the following steps to hang your HLA3105 on a wall. See Product Specifications for the size of screws to use and how far apart to place them. 1. Select a position free of obstructions on a sturdy wall. 2. Drill two holes for the screws. 1 Be careful to avoid damaging pipes or cables located inside the wall when drilling holes for the screws. 3. Do not insert the screws all the way into the wall. Leave a small gap of about 0.5 cm between the heads of the screws and the wall. 4. Make sure the screws are snugly fastened to the wall. They need to hold the weight of the HLA3105 with the connection cables. 5. Align the holes on the back of the HLA3105 with the screws on the wall. Hang the HLA3105 on the screws. The following are dimensions of an M4 tap screw and masonry plug used for wall mounting. All measurements are in millimeters (mm). Safety Warnings • Do NOT use this product near water, for example, in a wet basement or near a swimming pool. • Do NOT expose your device to dampness, dust or corrosive liquids. • Do NOT store things on the device. • Do NOT install, use, or service this device during a thunderstorm. There is a remote risk of electric shock from lightning. • Connect ONLY suitable accessories to the device. • Place connecting cables carefully so that no one will step on them or stumble over them. • Always disconnect all cables from this device before servicing or disassembling. • Do NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks. ONLY qualified service personnel should service or disassemble this device. Please contact your vendor for further information. • Use ONLY an appropriate power adaptor or cord for your device. Connect it to the right supply voltage (for example, 110V AC in North America or 230V AC in Europe). • Do NOT allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can walk on the power adaptor or cord. • Do NOT use the device if the power adaptor or cord is damaged as it might cause electrocution. • If the power adaptor or cord is damaged, remove it from the device and the power source. • Do NOT attempt to repair the power adaptor or cord. Contact your local vendor to order a new one. • Do not use the device outside, and make sure all the connections are indoors. There is a remote risk of electric shock from lightning. • Do NOT obstruct the device ventilation slots, as insufficient airflow may harm your device. • Make sure that the cable system is grounded so as to provide some protection against voltage surges. • Make sure to connect the cables to the correct ports. • Your product is marked with this symbol, which is known as the WEEE mark. WEEE stands for Waste Electronics and Electrical Equipment. It means that used electrical and electronic products should not be mixed with general waste. Used electrical and electronic equipment should be treated separately. www.zyxel.com Declaration of Conformity We, ZyXEL Communications Corp., located at No.6, Innovation Rd II, Science-Park, Hsin-Chu, 300, Taiwan, declare under our sole responsibility that the product: Product information Product Name Model Number Produced by : HomePNA 3.1 Coax Ethernet Bridge : HNA-101, HLA3105 Company Name : ZyXEL Communications Corporation Company Add. : No. 6, Innovation Road II, Science-Park, Hsin-Chu, 300, Taiwan to which this declaration relates, is in conformity with the following standards or other normative documents: EN 55022:2006+A1: 2007 EN 55024:1998+A1: 2001+A2: 2003 EN 61000-3-2: 2006 EN 61000-3-3: 2008 Safety EN 60950-1: 2006 +A11: 2009 COMMISSION REGULATION (EC) No 1275/2008 COMMISSION REGULATION (EC) No 278/2009 Following the provisions of 2004/108/EC; 92/31/EEC Directive; 93/68/EEC, 99/5/EEC , LVD 2006/95/EC, and ErP 2009/125/EC. In accordance with Annex III of the Directive 1999/5/EC. The TCF-File is located at: Company Name : ZyXEL Communications Czech s.r.o. Company Address : Modranska 621, 143 01 Praha 4, Czech Republic Person is responsible for marking this declaration: Milan Baran Name (Full Name) VP Operations Position/ Title 2010-05-10 Date Legal Signature 1/1

  • 1
  • 2

HLA3105 U
SER
S
G
UIDE
12/2010
Version 1.9.5, Edition 1
Copyright 2010 ZyXEL Communications Corp.
Product Specifications
Dimensions
112 mm (W) x 106 mm (D) x 28.5 mm
(H)
Device Weight
167 g
Two Coaxial
Connectors
IN
: connect to a coaxial outlet in the
home
OUT
: connect to a TV or set-top box
One RJ-45
Ethernet Port
Auto-negotiating: 10 Mbps or 100 Mbps
in either half-duplex or full-duplex mode.
Auto-crossover: Use either crossover or
straight-through Ethernet cables.
Power
Specification
Input: 100 - 240 VAC 50/60 Hz
Output: 5V 1A DC
Operating
Environment
Temperature: 0 ºC ~ 40 ºC
Humidity: 20%~ 85% RH (non-
condensing)
Storage
Environment
Temperature: -30 ºC ~ 60 ºC
Humidity: 20%~ 95% RH (non-
condensing)
Certifications
HomePNA
Safety
• CSA C22.2 No.60950-1
• UL 60950-1
• EN 60950-1
• IEC 60950-1
EMC
• European Union (CE mark):
EN55022 Class B (1998)
• North America:
FCC Part 15 (Class B)
Distance
between wall-
mounting
holes on
device's base
panel
75.8 mm
Screw size for
wall mounting
M4 Tap
Wall Mounting
It is recommended that you do NOT wall-mount the
HLA3105. Wall-mounting kit is not included.
Complete the following steps to hang your
HLA3105 on a wall.
See
Product Specifications
for the size of screws to
use and how far apart to place them.
1.
Select a position free of obstructions on a
sturdy wall.
2.
Drill two holes for the screws.
Be careful to avoid damaging pipes or
cables located inside the wall when drilling
holes for the screws.
3.
Do not insert the screws all the way into the
wall. Leave a small gap of about 0.5 cm
between the heads of the screws and the wall.
4.
Make sure the screws are snugly fastened to
the wall. They need to hold the weight of the
HLA3105 with the connection cables.
5.
Align the holes on the back of the HLA3105
with the screws on the wall. Hang the HLA3105
on the screws.
The following are dimensions of an M4 tap screw
and masonry plug used for wall mounting. All
measurements are in millimeters (mm).
Safety Warnings
• Do NOT use this product near water, for example, in a
wet basement or near a swimming pool.
• Do NOT expose your device to dampness, dust or
corrosive liquids.
• Do NOT store things on the device.
• Do NOT install, use, or service this device during a
thunderstorm. There is a remote risk of electric shock
from lightning.
• Connect ONLY suitable accessories to the device.
• Place connecting cables carefully so that no one will
step on them or stumble over them.
• Always disconnect all cables from this device before
servicing or disassembling.
• Do NOT open the device or unit. Opening or removing
covers can expose you to dangerous high voltage
points or other risks. ONLY qualified service personnel
should service or disassemble this device. Please
contact your vendor for further information.
• Use ONLY an appropriate power adaptor or cord for
your device. Connect it to the right supply voltage (for
example, 110V AC in North America or 230V AC in
Europe).
• Do NOT allow anything to rest on the power adaptor or
cord and do NOT place the product where anyone can
walk on the power adaptor or cord.
• Do NOT use the device if the power adaptor or cord is
damaged as it might cause electrocution.
• If the power adaptor or cord is damaged, remove it
from the device and the power source.
• Do NOT attempt to repair the power adaptor or cord.
Contact your local vendor to order a new one.
• Do not use the device outside, and make sure all the
connections are indoors. There is a remote risk of
electric shock from lightning.
• Do NOT obstruct the device ventilation slots, as
insufficient airflow may harm your device.
• Make sure that the cable system is grounded so as to
provide some protection against voltage surges.
• Make sure to connect the cables to the correct ports.
• Your product is marked with this
symbol, which is known as the WEEE
mark. WEEE stands for Waste
Electronics and Electrical Equipment. It
means that used electrical and
electronic products should not be mixed
with general waste. Used electrical and
electronic equipment should be treated
separately.
1/1
www.zyxel.com
Declaration of Conformity
We, ZyXEL Communications Corp., located at No.6, Innovation Rd II, Science-Park, Hsin-Chu,
300, Taiwan, declare under our sole responsibility that the product:
Product information
Product Name
:
HomePNA 3.1 Coax Ethernet Bridge
Model Number
:
HNA-101, HLA3105
Produced by
Company Name
:
ZyXEL Communications Corporation
Company Add.
:
No. 6, Innovation Road II, Science-Park, Hsin-Chu, 300, Taiwan
to which this declaration relates, is in conformity with the following standards or other
normative documents:
EN 55022:2006+A1: 2007
EN 55024:1998+A1: 2001+A2: 2003
EN 61000-3-2: 2006
EN 61000-3-3: 2008
COMMISSION REGULATION (EC)
No 1275/2008
COMMISSION REGULATION (EC)
No 278/2009
Safety EN 60950-1: 2006 +A11: 2009
Following the provisions of 2004/108/EC; 92/31/EEC Directive; 93/68/EEC, 99/5/EEC ,
LVD 2006/95/EC, and ErP 2009/125/EC.
In accordance with Annex III of the Directive 1999/5/EC.
The TCF-File is located at:
Company Name
:
ZyXEL Communications Czech s.r.o.
Company Address
:
Modranska 621, 143 01 Praha 4, Czech Republic
Person is responsible for marking this declaration:
Milan Baran
VP Operations
Name (Full Name)
Position/ Title
2010-05-10
Date
Legal Signature