ZyXEL P-334W User Guide - Page 378
SNMP Traps, Table 31-2 SNMP Traps, Table 31-3 Ports and Permanent Virtual Circuits
View all ZyXEL P-334W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 378 highlights
Prestige 334W User's Guide 31.4 SNMP Traps The Prestige will send traps to the SNMP manager when any one of the following events occurs: Table 31-2 SNMP Traps TRAP # 1 2 3 TRAP NAME coldStart (defined in RFC-1215) warmStart (defined in RFC-1215) linkDown (defined in RFC-1215) DESCRIPTION A trap is sent after booting (power on). A trap is sent after booting (software reboot). A trap is sent with the port number when any of the links are down. See the following table. 4 linkUp (defined in RFC-1215) A trap is sent with the port number. 5 authenticationFailure (defined in A trap is sent to the manager when receiving any SNMP RFC-1215) gets or sets requirements with wrong community (password). 6 whyReboot (defined in ZYXEL- A trap is sent with the reason of restart before rebooting MIB) when the system is going to restart (warm start). 6a For intentional reboot : A trap is sent with the message "System reboot by user!" if reboot is done intentionally, (for example, download new files, CI command "sys reboot", etc.). The port number is its interface index under the interface group. Table 31-3 Ports and Permanent Virtual Circuits PORT PVC (PERMANENT VIRTUAL CIRCUIT) 1 Ethernet LAN 2 1 3 2 ... ... 13 12 14 xDSL 31-4 SNMP Configuration