ZyXEL omni.net LCD User Guide - Page 39
COMMAND, DESCRIPTION, VALUE, DTE Phase C response time-out
View all ZyXEL omni.net LCD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Omni 56K Plus Series User's Guide COMMAND Table 4-9 Supported Commands (per TIA PN2388 8/20/90) DESCRIPTION VALUE +FDR +FDT=df,vr,wd, ln +FET=n +FK +FLID="string" +FLO=n +FLPL=n +FMDL? +FMFR? +FMINSP=n +FPHCTO= +FPTS=n Receive phase C data command; initiates document reception. Transmit phase C data command: release the DCE to proceed with negotiation. End of page or document command: More pages; same document. End of document; another document follows. No more pages or documents. Procedure interrupt; another page follows. Procedure interrupt; end of document, another document follows. Procedure interrupt; end of document. Regular fax abort command. Local ID string parameter. Flow control options: No flow control. Set XON/XOFF software flow control. Set CTS/RTS hardware flow control. Document for polling command: The DTE has no document available for polling. Indicate a document available for polling. Request DCE model. Request DCE manufacturer. Minimum phase C speed parameter: 2400 bps. 4800 bps. 7200 bps. 9600 bps. 12000 bps. 14400 bps. DTE Phase C response time-out: Determine how long the DCE will wait for a command after reaching the end of data when transmitting in Phase C. =0 to 255; 100 ms units. Page transfer status Received page good. Page bad; retrain requested. Page good; retrain requested. n=0 n=1 n=2 n=4 n=5 n=6 n=0 n=1 n=2 n=0 n=1 n=0 n=1 n=2 n=3 n=4 n=5 0-255 n=1 n=2 n=3 Command Sets 4-11