ASRock E350M1/USB3 User Manual - Page 31

Write to Read Delay tWTR - user manual

Page 31 highlights

RAS to RAS Delay (tRRD) Use this item to change RAS to RAS Delay (tRRD) Auto/Manual setting. The default is [Auto]. Write to Read Delay (tWTR) Use this item to change Write to Read Delay (tWTR) Auto/Manual setting. The default is [Auto]. Read to Precharge (tRTP) Use this item to change Read to Precharge (tRTP) Auto/Manual setting. The default is [Auto]. Four Activate Window (tFAW) Use this item to change Four Activate Window (tFAW) Auto/Manual setting. The default is [Auto]. Voltage Control DRAM Voltage Use this to select DRAM Voltage. Configuration options: [Auto], [1.300V] to [1.965V]. The default value is [Auto]. +1V Voltage Use this to select +1V Voltage. Configuration options: [Auto], [1.07V] to [1.16V]. The default value is [Auto]. FCH Voltage Use this to select FCH Voltage. Configuration options: [Auto], [1.10V] to [1.40V]. The default value is [Auto]. +1.8V Voltage Use this to select +1.8V Voltage. Configuration options: [Auto], [1.85V] to [2.10V]. The default value is [Auto]. User Default In this option, you are allowed to load and save three user defaults according to your own requirements. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

31
RAS to RAS Delay (tRRD)
Use this item to change RAS to RAS Delay (tRRD) Auto/Manual setting.
The default is [Auto].
Write to Read Delay (tWTR)
Use this item to change Write to Read Delay (tWTR) Auto/Manual setting.
The default is [Auto].
Read to Precharge (tRTP)
Use this item to change Read to Precharge (tRTP) Auto/Manual setting.
The default is [Auto].
Four Activate Window (tFAW)
Use this item to change Four Activate Window (tFAW) Auto/Manual
setting. The default is [Auto].
Voltage Control
DRAM Voltage
Use this to select DRAM Voltage. Con
guration options: [Auto], [1.300V]
to [1.965V]. The default value is [Auto].
+1V Voltage
Use this to select +1V Voltage. Con
guration options: [Auto], [1.07V] to
[1.16V]. The default value is [Auto].
FCH Voltage
Use this to select FCH Voltage. Con
guration options: [Auto], [1.10V] to
[1.40V]. The default value is [Auto].
+1.8V Voltage
Use this to select +1.8V Voltage. Con
guration options: [Auto], [1.85V] to
[2.10V]. The default value is [Auto].
User Default
In this option, you are allowed to load and save three user defaults
according to your own requirements.