ASRock K8A780LM User Manual - Page 39

Memory Timing, CAS Latency, MA Timing, Burst Length, Bank Interleaving

Page 39 highlights

Memory Timing BIOS SETUP UTILITY OC Tweaker Memory Timing CAS Latency TRAS TRP TRCD TRRD TRC MA Timing Burst Length Bank Interleaving [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [4 Beats] [Auto] +F1 F9 F10 ESC Select Screen Select Item Change Option General Help Load Defaults Save and Exit Exit v02.54 (C) Copyright 1985-2003, American Megatrends, Inc. CAS Latency Use this item to adjust the means of memory accessing. Configuration options: [Auto], [2T], [2.5T] and [3T]. The default value is [Auto]. TRAS Use this to adjust TRAS values. Configuration options: [Auto], [5T] to [12T]. The default value is [Auto]. TRP Use this to adjust TRP values. Configuration options: [Auto], [2T] to [6T]. The default value is [Auto]. TRCD Use this to adjust TRCD values. Configuration options: [Auto], [2T] to [6T]. The default value is [Auto]. TRRD Use this to adjust TRRD values. Configuration options: [Auto], [2T] to [4T]. The default value is [Auto]. TRC Use this to adjust TRC values. Configuration options: [Auto], [7T] to [14T]. The default value is [Auto]. MA Timing Use this to adjust values for MA timing. Configuration options: [Auto], [2T], [1T]. The default value is [Auto]. Burst Length Burst length can be set to 8, 4 or 2 beats. 64 Bit Dq must use the 4 beats. Bank Interleaving Interleaving allows memory accesses to be spread out over banks on the same node, or accross nodes, decreasing access contention. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

39
39
39
39
39
BIOS SETUP UTILITY
Memory Timing
Select Screen
Select Item
+-
Change Option
F1
General Help
F9
Load Defaults
F10
Save and Exit
ESC
Exit
v02.54 (C) Copyright 1985-2003, American Megatrends, Inc.
OC Tweaker
Select Screen
Select Item
+-
Change Option
F1
General Help
F9
Load Defaults
F10
Save and Exit
ESC
Exit
CAS Latency
[Auto]
TRAS
TRP
TRCD
TRRD
TRC
MA Timing
Burst Length
Bank Interleaving
[Auto]
[Auto]
[Auto]
[Auto]
[Auto]
[Auto]
[4 Beats]
[Auto]
Memory Timing
CAS Latency
Use this item to adjust the means of memory accessing. Configuration
options: [Auto], [2T], [2.5T] and [3T]. The default value is [Auto].
TRAS
Use this to adjust TRAS values. Configuration options: [Auto], [5T] to [12T].
The default value is [Auto].
TRP
Use this to adjust TRP values. Configuration options: [Auto], [2T] to [6T].
The default value is [Auto].
TRCD
Use this to adjust TRCD values. Configuration options: [Auto], [2T] to [6T].
The default value is [Auto].
TRRD
Use this to adjust TRRD values. Configuration options: [Auto], [2T] to [4T].
The default value is [Auto].
TRC
Use this to adjust TRC values. Configuration options: [Auto], [7T] to [14T].
The default value is [Auto].
MA Timing
Use this to adjust values for MA timing. Configuration options: [Auto], [2T],
[1T]. The default value is [Auto].
Burst Length
Burst length can be set to 8, 4 or 2 beats. 64 Bit Dq must use the 4 beats.
Bank Interleaving
Interleaving allows memory accesses to be spread out over banks on the
same node, or accross nodes, decreasing access contention.