3.5 Hardware Health Event Monitoring Screen In this section, it allows you to monitor the status of the hardware on your system, including the parameters of the CPU temperature, motherboard temperature, CPU fan speed, chassis fan speed, and the critical voltage. BIOS SETUP UTILITY Main OC Tweaker Advanced H/W Monitor Boot Security Exit Hardware Health Event Monitoring CPU Temperature M/B Temperature : 37 C / 98 F : 31 C / 87 F CPU Fan Speed Chassis Fan1 Speed Chassis Fan2 Speed Chassis Fan3 Speed Power Fan Speed : N/A : N/A : N/A : N/A : N/A Vcore + 3.30V + 5.00V + 12.00V CPU Fan Setting Chassis Fan 1 Setting Chassis Fan 2 Setting Chassis Fan 3 Setting : 1.152V : 3.312V : 11.968V : 5.080V F1 F9 F10 ESC Select Screen Select Item General Help Load Defaults Save and Exit Exit v02.54 (C) Copyright 1985-2003, American Megatrends, Inc. CPU Fan Setting This allows you to set the CPU fan speed. Configuration options: [Full On] and [Automatic mode]. The default is value [Full On]. Chassis Fan 1 Setting This allows you to set the chassis fan 1 speed. Configuration options: [Full On] and [Manual Mode]. The default is value [Full On]. Chassis Fan 2 Setting This allows you to set the chassis fan 2 speed. Configuration options: [Level 1], [Level 2], [Level 3] and [Level 4]. The default is value [Level 4]. Chassis Fan 3 Setting This allows you to set the chassis fan 3 speed. Configuration options: [Full On] and [Manual mode]. The default is value [Full On]. 66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

66
66
66
66
66
BIOS SETUP UTILITY
Hardware Health Event Monitoring
Select Screen
Select Item
F1
General Help
F9
Load Defaults
F10
Save and Exit
ESC
Exit
v02.54 (C) Copyright 1985-2003, American Megatrends, Inc.
CPU Temperature
M/B Temperature
CPU Fan Speed
Chassis Fan1 Speed
Chassis Fan2 Speed
Chassis Fan3 Speed
Power Fan Speed
Vcore
+ 3.30V
+ 5.00V
+ 12.00V
: 37 C / 98 F
: N/A
: 31 C / 87 F
: N/A
: N/A
: N/A
: N/A
: 1.152V
: 3.312V
: 11.968V
: 5.080V
Main
OC Tweaker
Advanced
Boot
Security
Exit
H/W Monitor
CPU Fan Setting
Chassis Fan 1 Setting
Chassis Fan 2 Setting
Chassis Fan 3 Setting
3.5
3.5
3.5
3.5
3.5 Hardware Health Event Monitoring Screen
Hardware Health Event Monitoring Screen
Hardware Health Event Monitoring Screen
Hardware Health Event Monitoring Screen
Hardware Health Event Monitoring Screen
In this section, it allows you to monitor the status of the hardware on your system,
including the parameters of the CPU temperature, motherboard temperature, CPU fan
speed, chassis fan speed, and the critical voltage.
CPU Fan Setting
This allows you to set the CPU fan speed. Configuration options: [Full On]
and [Automatic mode]. The default is value [Full On].
Chassis Fan 1 Setting
This allows you to set the chassis fan 1 speed. Configuration options:
[Full On] and [Manual Mode]. The default is value [Full On].
Chassis Fan 2 Setting
This allows you to set the chassis fan 2 speed. Configuration options:
[Level 1], [Level 2], [Level 3] and [Level 4]. The default is value [Level 4].
Chassis Fan 3 Setting
This allows you to set the chassis fan 3 speed. Configuration options:
[Full On] and [Manual mode]. The default is value [Full On].