Note : 2.2k, to Ground, Schmitt-Triggers Input, Supported 3.3V device H & V sync. Output.
View all Acer AL2002 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
D. Flat Panel Connector 6 Go to cover page 3.4. Input Signals (Analog RGB Signal Input): 3.4.1. Video Input Signal Ranges No. Symbol Item Min Normal Max Unit Remark 1 Fh Horizontal Frequency 30 81 kHz Minimum range 2 Fv Vertical Frequency 56 76 Hz Minimum range 3 Fclk Locked Pixel Clock Frequency 165 MHz 4 Vih Hi Level Input 2.0 5.0 V Note 1) 5 Vil Low Level Input 0 0.8 V Note 1) 6 Video RGB Analog Video Level 0.0 0.735 V 75Ω to Ground Note : 2.2kΩ to Ground, Schmitt-Triggers Input, Supported 3.3V device H & V sync. Output.