Unpackaged Shock Test Non-operating, Operating Shock Test

Page 18 highlights

Frequency 5 ~ 500 Hz 5Hz @ 0.0001 g^2/Hz to 20Hz @ 0.01 g^2/Hz (slope up) 20Hz to 500 Hz @ 0.01g^2/Hz (flat) Acceleration 2.20 g RMS Test Axis: 3 axes Test Time: 10 minutes (per axis; total 3 axes) Vibration Packaged Frequency 5 ~ 300 Hz 0.015 g^2/Hz from 5 to 40 Hz Sloping to 0.00015 g^2/Hz @ 500 Hz (slope down) Acceleration 1.20 g RMS random Test Axis: 3 axes Test Time: 30 minutes (per axis; total 3 axes) Operating Shock Test Half sine, 40G , 2mSec Unpackaged Shock Test (Non-operating) Half sine, 80G, 1650mm/sec, 3mSec 1-10 Hardware Specifications and Configurations