Amana AGR4433XDB Installation Instruction - Page 12

To Convert Surface Burners

Page 12 highlights

2. Unplug range or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A 2. Locate LP gas orifice spuds for top burners in the literature bag included with the range. Three LP gas spuds are stamped "88" and one "96." 3. Remove Natural gas orifice spuds using a 7 mm combination wrench. 4. Install LP gas orifice spuds using a 7 mm combination wrench. A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver. NOTE: Do not remove the spring beneath the cap. A A. Cap 5. Turn the cap over so the LP is visible. A A B A. Spud B. Holder NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 super burner. Spud size and location remain the same. For models with 4 standard burners: Std burner 88 Std burner 88 Std burner 88 Std burner 88 6. Reinstall the cap. A. Cap To Convert Surface Burners 1. Remove burner grate, burner caps and burners. A B For models with 3 standard burners and 1 super burner: Std burner 88 Super burner 96 Std burner 88 Std burner 88 A. Burner cap B. Burner 12 5. Place the Natural gas orifice spuds in the parts bag for future use and keep with the bag containing literature. 6. Reinstall burners, burner caps and burner grates.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

12
2.
Unplug range or disconnect power.
3.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
4.
Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE:
Do not remove the spring beneath the cap.
5.
Turn the cap over so the LP is visible.
6.
Reinstall the cap.
To Convert Surface Burners
1.
Remove burner grate, burner caps and burners.
2.
Locate LP gas orifice spuds for top burners in the literature
bag included with the range. Three LP gas spuds are
stamped “88” and one “96.”
3.
Remove Natural gas orifice spuds using a 7 mm combination
wrench.
4.
Install LP gas orifice spuds using a 7 mm combination
wrench.
NOTE:
Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and
1 super burner. Spud size and location remain the same.
For models with 4 standard burners:
For models with 3 standard burners and 1 super burner:
5.
Place the Natural gas orifice spuds in the parts bag for future
use and keep with the bag containing literature.
6.
Reinstall burners, burner caps and burner grates.
A. Gas pressure regulator
A. Cap
A. Cap
A. Burner cap
B. Burner
A
A
A
A
B
A. Spud
B. Holder
A
B
Std burner 88
Std burner 88
Std burner 88
Std burner 88
Std burner 88
Std burner 88
Std burner 88
Super burner 96