Amana AGR4433XDB Installation Instruction - Page 12
To Convert Surface Burners
UPC - 883049206387
View all Amana AGR4433XDB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
2. Unplug range or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A 2. Locate LP gas orifice spuds for top burners in the literature bag included with the range. Three LP gas spuds are stamped "88" and one "96." 3. Remove Natural gas orifice spuds using a 7 mm combination wrench. 4. Install LP gas orifice spuds using a 7 mm combination wrench. A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver. NOTE: Do not remove the spring beneath the cap. A A. Cap 5. Turn the cap over so the LP is visible. A A B A. Spud B. Holder NOTE: Depending on model, the range cooktop may be equipped with 4 standard burners or 3 standard burners and 1 super burner. Spud size and location remain the same. For models with 4 standard burners: Std burner 88 Std burner 88 Std burner 88 Std burner 88 6. Reinstall the cap. A. Cap To Convert Surface Burners 1. Remove burner grate, burner caps and burners. A B For models with 3 standard burners and 1 super burner: Std burner 88 Super burner 96 Std burner 88 Std burner 88 A. Burner cap B. Burner 12 5. Place the Natural gas orifice spuds in the parts bag for future use and keep with the bag containing literature. 6. Reinstall burners, burner caps and burner grates.