Connecting a 4-wire Power Cord, Power Supply Cord

Page 25 highlights

Installation instructions 5. Connect ground (center) wire of power supply cord to the center, silver-colored terminal screw. Tighten screw. 6. Connect the other wires to outer screws. 7. Tighten the strain relief screws. 8. Replace terminal box cover on back of dryer. 9. Plug dryer into wall receptacle. 10. Turn power on at breaker/fuse box. Connecting a 4-wire Power Cord Warning! Before starting this procedure, be sure the power is turned off at the breaker/fuse box. 4 7 8 6 5. Remove ground wire (green with yellow stripes) from external ground connector screw and remove from center terminal block. 6. Connect ground (green) wire of cord to external ground conductor screw. 7. Connect neutral (white) wire of cord under center screw of terminal block. 8. Connect the other wires to outer screws. 9. Tighten the strain relief screws. 10. Replace terminal box cover on back of dryer. 11. Plug dryer into wall receptacle. 12. Turn power on at breaker/fuse box. Power Supply Cord You will need a 4-wire power supply cord with four No. 10 copper wires and a matching 4-wire receptacle of NEMA Type 14-30R, as illustrated below. The fourth wire must be identified with a white cover and the ground conductor by a green cover. To connect a 4-wire power cord to the dryer, follow the steps below. Note The numbers in the illustration below correlate to the step numbers. 1. Turn the power off at the breaker/fuse box. 2. Remove terminal block cover. 3. Use the strain relief attached below the termi- nal block opening. 4. Remove center terminal block screw. Customer Care Center 25 1-800-898-1879 www.askousa.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

5. Connect ground (center) wire of power supply
cord to the center, silver-colored terminal
screw. Tighten screw.
6. Connect the other wires to outer screws.
7. Tighten the strain relief screws.
8. Replace terminal box cover on back of dryer.
9. Plug dryer into wall receptacle.
10.Turn power on at breaker/fuse box.
Connecting a 4-wire Power Cord
Warning!
Before starting this procedure, be sure the power
is turned off at the breaker/fuse box.
Power Supply Cord
You will need a 4-wire power supply cord with four
No. 10 copper wires and a matching 4-wire recep-
tacle of NEMA Type 14-30R, as illustrated below.
The fourth wire must be identified with a white
cover and the ground conductor by a green cover.
To connect a 4-wire power cord to the dryer, fol-
low the steps below.
Note
The numbers in the illustration below correlate to
the step numbers.
1. Turn the power off at the breaker/fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the termi-
nal block opening.
4. Remove center terminal block screw.
4
6
7
8
5. Remove ground wire (green with yellow
stripes) from external ground connector screw
and remove from center terminal block.
6. Connect ground (green) wire of cord to external
ground conductor screw.
7. Connect neutral (white) wire of cord under
center screw of terminal block.
8. Connect the other wires to outer screws.
9. Tighten the strain relief screws.
10.Replace terminal box cover on back of dryer.
11.Plug dryer into wall receptacle.
12.Turn power on at breaker/fuse box.
25
Customer Care Center
1-800-898-1879
www.askousa.com
Installation instructions