Asus ESC4000 FDR G2 User Guide - Page 43
ASUS ESC4000 G2 Series, 100V-120Vac, 12-10A, 50-60Hz, 120V-140Vac, 12-10A, 50-60Hz, 180V-240Vac, 10.
View all Asus ESC4000 FDR G2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
3. Insert the PSU into the empty PSU bay. • The system automatically combines the two power supply modules as a single one. The combined output power varies with input voltages. Refer to the table below for details. Input Voltage 100V-120Vac, 12-10A, 50-60Hz 120V-140Vac, 12-10A, 50-60Hz 180V-240Vac, 10.5-8A, 50-60Hz Max. Output Power (Watt) per PSU 1000W 1200W 1620W • To enable the hot-swap feature (redundant mode), keep the total power consumption of the system under the maximum output power of an individual power supply module. • For steady power input, use only the power cables that come with the server system package. ASUS ESC4000 G2 Series 2-21
2-21
ASUS ESC4000 G2 Series
3.
Insert the PSU into the empty PSU
bay.
•
The system automatically combines the two power supply modules as a
single one. The combined output power varies with input voltages. Refer to
the table below for details.
Input Voltage
Max. Output Power (Watt) per PSU
100V—120Vac, 12-10A, 50-60Hz
1000W
120V—140Vac, 12-10A, 50-60Hz
1200W
180V—240Vac, 10.5-8A, 50-60Hz
1620W
•
To enable the hot-swap feature (redundant mode), keep the total power
consumption of the system under the maximum output power of an
individual power supply module.
•
For steady power input, use only the power cables that come with the
server system package.