Behringer 297 DUAL PORTAMENTO/CV UTILITIES Quick Start Guide
Behringer 297 DUAL PORTAMENTO/CV UTILITIES Manual
View all Behringer 297 DUAL PORTAMENTO/CV UTILITIES manuals
Add to My Manuals
Save this manual to your list of manuals |
Behringer 297 DUAL PORTAMENTO/CV UTILITIES manual content summary:
- Behringer 297 DUAL PORTAMENTO/CV UTILITIES | Quick Start Guide - Page 1
Quick Start Guide SYSTEM 100 297 DUAL PORTAMENTO/ CV UTILITIES Legendary Analog Portamento Controller and CV Utilities for Eurorack Controls (1) (2) (3) (6) NON INV OUT - Send the mix of inputs 1-4 - Behringer 297 DUAL PORTAMENTO/CV UTILITIES | Quick Start Guide - Page 2
Installation The necessary screws are included with the module for mounting in a Eurorack case. Connect the power cable before mounting. Depending on the rack case, there may be a series of fixed holes spaced 2 HP apart along the length of the case, or a track that allows individual threaded plates
V 1.0
Quick Start Guide
SYSTEM 100
297 DUAL PORTAMENTO/
CV UTILITIES
Legendary Analog Portamento
Controller and CV Utilities for Eurorack
Controls
(1)
MIXER SIG IN
– Connect incoming signals via 3.5 mm
TS cables. Inputs 3 and 4 feed +10/-10 V respectively to
the mixer inputs if no jack is inserted, which can be used
to offset the overall mixer output control voltage.
(2)
PORTA SIG OUT
– Send the portamento signal to another
module via 3.5 mm TS cable.
(3)
PORTA SIG IN
– Connect a signal to the portamento
section via 3.5 mm TS cable.
(4)
SIG LEVEL
– Adjust the level of the signals connected to
the mixer inputs.
(5)
INV OUT
– Send the mix of inputs 1-4 as an
inverted signal.
(6)
NON INV OUT
– Send the mix of inputs 1-4 as a
non-inverted signal.
(7)
TIME
– Adjust the portamento time.
(8)
CV IN
– Connect a voltage to control the portamento time
from another module.
(9)
+10/-10 V LEVEL
– Adjust the level of the +10 V and
-10 V outputs.
(10)
+10/-10 V OUT
– Send the +10 V and -10 V signals via
3.5 mm TS cable.
Power Connection
The module comes with the required power cable for connecting
to a standard Eurorack power supply system. Follow these
steps to connect power to the module. It is easier to make
these connections before the module has been mounted into
a rack case.
1.
Turn the power supply or rack case power off and
disconnect the power cable.
2.
Insert the 16-pin connector on the power cable into the
socket on the power supply or rack case. The connector has
a tab that will align with the gap in the socket, so it cannot
be inserted incorrectly. If the power supply does not have
a keyed socket, be sure to orient pin 1 (-12 V) with the red
stripe on the cable.
3.
Insert the 10-pin connector into the socket on the back of
the module. The connector has a tab that will align with the
socket for correct orientation.
4.
After both ends of the power cable have been securely
attached, you may mount the module in a case and turn on
the power supply.
(1)
(4)
(5)
(6)
(3)
(2)
(7)
(8)
(10)
(9)