Bosch DHR-753-16A200 Product Guide - Page 3

Installation/Configuration Notes, Parts Included, Technical Specifications

Page 3 highlights

700 Series Hybrid/Network Recorder | 3 Electromagnetic compatibility Mains Harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 Alarm standard EN50130-5:1998 Safety USA EU Can UL60950-1 EN60950-1 CSA C22.2 No. 60950-1 Installation/Configuration Notes Recommended PC requirements for Control Center Operating system Processor RAM memory Free disk space Graphics card Network interface Windows XP, Vista, or 7 DirectX 9c Intel Pentium DualCore, 3.0 GHz or comparable 2048 MB or more 10 GB NVIDIA GeForce 8600 or higher 10/100/1000 BaseT 15 14 123 4 5 6 78 9 10 x16 - |+ | G RS 485 KBD in Ethernet B B B Com 1 A A A L Com 2 1 3 5 7 9 11 13 15 MAL OUT N0 | C | NC KBD out USB USB IR ext VGA Monito r out CVBS Y/C Biph ase Alarm I/O R A B 2 4 6 8 10 12 14 16 Audio out Audio in AC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Video in Video in Video in 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Video out Video out Video out Secondary Ethernet x16 13 12 11 1 Keyboard input and looped-through output 2 Ethernet 3 USB ports 4 B monitor connections (VGA, CVBS, Y/C) 5 A monitor connections (VGA, CVBS, Y/C) 6 Biphase connection 7 Alarm inputs 8 Alarm outputs 9 Audio outputs 10 Audio inputs 11 Secondary Ethernet (2 GigE versions) 12 Camera loop through 13 Power input 14 Malfunction alarm output 15 RS485 port 123 45 67 11 10 - |+ | G RS 485 KBD in MAL OUT N0 | C | NC KBD out AC Ethernet USB USB IR ext VGA Monito r out CVBS Y/C Com 1 Biph ase Com 2 Alarm I/O L R A Audio out 9 1 Keyboard input and looped-through output 2 Ethernet 3 USB ports 4 Monitor connections (VGA, CVBS, Y/C) 5 Biphase connection 6 Alarm inputs 7 Alarm outputs 8 Secondary Ethernet (2 GigE versions) 9 Power input 10 Malfunction alarm output 11 RS485 port Secondary Ethernet 8 Parts Included Quantity 1 2 1 1 1 1 1 1 Component Divar 700 Series Recorder Power supply cords USB mouse CD-ROM containing the software and manuals Quick installation guide Installation and operation manual Divar 700 Series Control Center operation manual Divar 700 Series Archive Player operation manual Technical Specifications Electrical Rated Voltage and Power Power input 100 to 240 VAC; 50/60 Hz Power consumption Max. 2.5 to 1.0 A (250 Watt) Able to withstand power dips up to 100 MS, assuring continuous operation www.boschsecurity.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

700 Series Hybrid/Network Recorder |
3
Electromagnetic compatibility
Mains Harmonics
EN61000-3-2
Voltage fluctuations
EN61000-3-3
Alarm standard
EN50130-5:1998
Safety
USA
UL60950-1
EU
EN60950-1
Can
CSA C22.2 No. 60950-1
Installation/Configuration Notes
Recommended PC requirements for Control Center
Operating system
Windows XP, Vista, or 7
DirectX 9c
Processor
Intel Pentium DualCore, 3.0 GHz or comparable
RAM memory
2048 MB or more
Free disk space
10 GB
Graphics card
NVIDIA GeForce 8600 or higher
Network interface
10/100/1000 BaseT
KBD in
KBD out
IR ext
VGA
CVBS
Y/C
Biph ase
Com 1
Com 2
Alarm I/O
A
B
A
A
B
B
- | + | G
RS
485
MAL
OUT
N0 | C | NC
Video in
Video out
Video in
Video out
Video in
Video out
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
AC
USB
USB
Ethernet
Audio out
Audio in
A
B
L
R
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
Monito r out
Secondary Ethernet
x16
x16
11
1
2
9
10
12
4
5
6
8
3
14
15
13
7
1
Keyboard input and looped-through output
2
Ethernet
3
USB ports
4
B monitor connections (VGA, CVBS, Y/C)
5
A monitor connections (VGA, CVBS, Y/C)
6
Biphase connection
7
Alarm inputs
8
Alarm outputs
9
Audio outputs
10
Audio inputs
11
Secondary Ethernet (2 GigE versions)
12
Camera loop through
13
Power input
14
Malfunction alarm output
15
RS485 port
KBD in
KBD out
IR ext
VGA
CVBS
Y/C
Biph ase
Com 1
Com 2
Alarm I/O
- | + | G
RS
485
MAL
OUT
N0 | C | NC
AC
USB
USB
Ethernet
Audio out
A
L
R
Monito r out
Secondary Ethernet
1
2
9
8
4
5
7
3
11
10
6
1
Keyboard input and looped-through output
2
Ethernet
3
USB ports
4
Monitor connections (VGA, CVBS, Y/C)
5
Biphase connection
6
Alarm inputs
7
Alarm outputs
8
Secondary Ethernet (2 GigE versions)
9
Power input
10
Malfunction alarm output
11
RS485 port
Parts Included
Quantity
Component
1
Divar 700 Series Recorder
2
Power supply cords
1
USB mouse
1
CD-ROM containing the software and manuals
1
Quick installation guide
1
Installation and operation manual
1
Divar 700 Series Control Center operation manual
1
Divar 700 Series Archive Player operation manual
Technical Specifications
Electrical
Rated Voltage and Power
Power input
100 to 240 VAC; 50/60 Hz
Power consumption
Max. 2.5 to 1.0 A (250 Watt)
Able to withstand power dips up to 100 MS, as-
suring continuous operation
www.boschsecurity.com