Bosch HBN5650UC Installation Instructions - Page 13

Electrical Connection, Four-wire Connection, Three-wire Connection

Page 13 highlights

Electrical Connection The four-wire connection is preferred, but where local codes permit, the three wire connection is also acceptable. Four-wire Connection • Connect the red oven wire to the red electrical supply wire (hot wire). • Connect the black oven wire to the black electrical supply wire (hot wire). • Connect the white neutral oven wire to the white neutral (not bare ground) electrical supply wire. • Connect the bare ground oven wire to the bare ground electrical supply wire. Three-wire Connection • Connect red wire from oven to red wire injunction box. • Connect black wire from oven to black wire in junction box. • Connect both green ground wire and white wire from oven to white (or gray) neutral wire in junction box. The conduit cable, where connected at the oven, swivels. Rotate conduit cable upward (or downward) and direct through hole prepared in cabinet to attach to JBox. To maintain serviceability, the flex conduit must not be shortened and should be routed to permit temporary removal of the oven. English 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

English 11
Electrical Connection
The four-wire connection is preferred, but where local codes permit, the three wire
connection is also acceptable.
Four-wire Connection
Connect the red oven wire to the red electrical supply wire (hot wire).
Connect the black oven wire to the black electrical supply wire (hot wire).
Connect the white neutral oven wire to the white neutral (not bare ground)
electrical supply wire.
Connect the bare ground oven wire to the bare ground electrical supply wire.
Three-wire Connection
Connect red wire from oven to red wire injunction box.
Connect black wire from oven to black wire in junction box.
Connect both green ground wire and white wire from oven to white (or gray)
neutral wire in junction box.
The conduit cable, where connected at the oven, swivels. Rotate conduit cable
upward (or downward) and direct through hole prepared in cabinet to attach to J-
Box.
To maintain serviceability, the flex conduit must not be shortened and should be
routed to permit temporary removal of the oven.