Preparation Before you Begin Tools and Parts Needed Parts Included 27" Appliances • Phillips head screwdriver • Measuring tape • Drill with bit (1/8") • Phillips head screws (6) General Information Power Requirements The outlet must be properly grounded in accordance with all applicable codes. Dimensions for 27" Wall-Mounted Units 24" (610mm) 251/2" (648mm) 263/4" (680mm) 2413/16" (630mm) 281/4" (718mm) 291/16" (738mm) 27" (686mm) min. 43/4" (121mm) max. 313/8" (797mm) 237/8" (606mm) 22" (559mm) Single Oven 27" It is good practice, when oven is installed at the end of a cabinet run, adjacent to a perpendicular wall or cabinet door, to allow at least 1/4" space between the side of the oven and the wall/door. For oven support, install 2x4's extending front to back flush with the bottom and the side of the opening. The supporting base must be well secured to the floor/cabinet and level. Note: The conduit box must be installed either above or below the unit. If the conduit box is installed below the unit, a 2" diameter hole or space is required between the back wall and the right rear of the 2x4 supports. The cabinet base must be flat and capable of supporting a weight of at least 210 lbs (95 kg). English 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

English 3
Preparation
Before you Begin
Tools and Parts Needed
Phillips head screwdriver
Measuring tape
Drill with bit (1/8")
Parts Included
Phillips head screws (6)
27” Appliances
General Information
Power Requirements
The outlet must be properly grounded in accordance with all applicable codes.
Dimensions for 27” Wall-Mounted Units
25
1/2"
(648mm)
28
1/4"
(718mm)
27
"
(686mm)
24
13/16"
(630mm)
min. 4
3/4"
(121mm)
max. 31
3/8"
(797mm)
24
"
(610mm)
23
7/8"
(606mm)
22
"
(559mm)
29
1/16"
(738mm)
26
3/4"
(680mm)
Single Oven 27”
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4”
space between the side of the oven and
the wall/door.
For oven support, install 2x4’s
extending front to back flush with the
bottom and the side of the opening. The
supporting base must be well secured
to the floor/cabinet and level.
Note:
The conduit box must be installed
either above or below the unit. If the
conduit box is installed below the unit, a
2” diameter hole or space is required
between the back wall and the right rear
of the 2x4 supports.
The cabinet base must be flat and
capable of supporting a weight of at
least 210 lbs (95 kg).