Brother International 1800C Service Manual - Page 164
transmission
UPC - 012502603764
View all Brother International 1800C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 164 highlights
Selector No. 1 2 3 4 5 6 7 8 WSW10 (Protocol definition 2) Function Not used. Time length from transmission of the last dial digit to CML ON Time length from CML ON to CNG transmission Time length from CML ON to CED transmission (except for facsimile-to-telephone switching) No. of training retries Encoding system (Compression) MR MMR Setting and Specifications 0: 100 ms 0: 2 sec. 1: 50 ms 1: 4 sec. 0: 0.5 sec. 1: 2 sec. No. 5 6 0 0 : 1 time 0 1 : 2 times 1 0 : 3 times 1 1 : 4 times 0: Allowed 1: Not allowed 0: Allowed 1: Not allowed • Selector 2: Time length from transmission of the last dial digit to CML ON This selector sets the time length from when the equipment transmits the last dial digit until the CIVIL relay comes on. • Selector 3: Time length from CML ON to CNG transmission This selector sets the time length until the equipment transmits a CNG after it turns on the CIVIL relay. • Selector 4: Time length from CML ON to CED transmission This selector sets the time length until the equipment transmits a CED after it turns on the CML relay. This setting does not apply to switching between facsimile and telephone. • Selectors 5 and 6: No. of training retries These selectors set the number of training retries to be repeated before automatic fallback. • Selectors 7 and 8: Encoding system (Compression) This selector determines whether or not use of the MR/MMR coding system will be allowed. 13