11. TABLE OF ERROR CODES Data editing-related errors Code Cause and remedy E500 The enlargement ratio setting caused the sewing data to extend outside the sewing area. Set the enlargement ratio again. E501 Sewing data that exceeds the sewing machine's sewing area was loaded. Check the size of the sewing data. E502 The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm. Set the enlargement ratio again. E510 Invalid code in sewing data. Reload the data from the CF card or floppy disk. E511 E512 No end code has been input into sewing data. Input an end code, or change the program number. Number of stitches exceeds allowed maximum. E520 E530 Extended option output number already exists. Change the extended option output number. If not using the extended option output, initialize the data to clear the extended option output data. Changing program number is prohibited. PCB-related errors Code Cause and remedy E700 Abnormal rise in power supply voltage. Turn off the power and check the input voltage. E701 Abnormal rise in sewing machine motor drive voltage. Turn off the power, and then check the voltage. E705 Abnormal drop in power supply voltage. Turn off the power and check the input voltage. E710 Abnormal current detected in sewing machine motor. Turn off the power, and then check if there are any problems with the sewing machine. E711 Abnormal current detected in X-feed motor. Turn off the power, and then check if there are any problems in the X-feed direction. E712 Abnormal current detected in Y-feed motor. Turn off the power, and then check if there are any problems in the Y-feed direction. Abnormal current detected in work clamp motor. E713 Turn off the power, and then check if there are any problems with the X-feed mechanism, Y-feed mechanism or work clamp lifter. E730 External error input (AIRSW) detected. Turn off the power, and then check the air pressure. Cooling fan does not operate. E740 Turn off the power, and then check if the cooling fan is blocked with scraps of thread. Check that connector P22 on the main PCB is properly connected. If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem, contact the place of purchase. BAS-300G, BAS-311G, BAS-326G 70