Brother International BAS-342E Programmer Instruction Manual - English - Page 81
Ending program, Canceling thread breakage at the last stitch, Programming
View all Brother International BAS-342E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Chapter 2 Programming with Help Function Ending program 1. Press P . Canceling thread breakage at the last stitch Stitch length Addition of feed after the last point can cancel thread breakage at the last stitch. When "115" is input for the end code, the thread breakage does not occur. In this case, every thread breakage including emergency stop is canceled. Carry out the following setting for canceling thread breakage at the specified point. Programming 1. Create the program 1 stitch (A) before the desired end point. 2. Press . ESC The number of pressing varies depending on the programming method. 3. Select with and press . 4. Move the work clamp with for the stitch length. Press when the needle point is at point B of the pattern. Point B is programmed. 5. Press . ESC 80 Programmer