Brother International DB2-B773 Service Manual - Page 39
Adjusting, timing, upper, horizontal, movement
View all Brother International DB2-B773 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Adjusting the timing of upper feed horizontal movement 0 0 e I) 0 O co Upper feed dog L=E I Feed dog 1 mm 1.5 mm [DB-B774-0031 When the presser foot is positioned back [DB-B774-006] When the presser foot is aligned with the reference line 1) Maximize the upper feed amount by turning the upper feed regulating plate assembly. 2) Maximize the feed amount by turning the length control assembly. 3) Remove the screw 0 and the upper cover 0. 4) Loosen the screws 0. 5) While slowly rotating the machine pulley in its normal rotating direction, press down and pull up the reverse lever 0, and stop moving it where the feed dog stops. NOTE: There are two positions for the adjustment described above; above and below the needle plate. For this adjustment, use the above-the-plate position only. 6) While slowly rotating the eccentric wheel 0, push down and pull up the reverse lever 0, stop moving it where the upper feed dog stops, and tighten the screw 0. Adjusting the clearance between the upper feed dog and the presser foot 1) Remove the face plate. 2) Maximize the upper feed amount by turning the upper feed regulating plate assembly. 3) Slowly rotate the machine pulley. 4) The clearance between the upper feed dog and the presser foot when the two come nearest should be about 1mm for the pucker type, and 1.5mm for the gather type. 5) Loosen the screw (5, and adjust the clearance by moving the upper feed arm 0 forward and backward. -35-