Casio FX-9860GII-L-IH User Guide - Page 577
Function, Input range for real, number solutions, Internal, digits, Precision, Notes
View all Casio FX-9860GII-L-IH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 577 highlights
α-2-2 Input Ranges Function Input range for real number solutions Pol (x, y) x2 + y2 < 1 × 10100 Rec (r ^ (x y) |r| < 1 × 10100 (DEG) |θ | < 9 × (109)° (RAD) |θ | < 5 × 107π rad (GRA) |θ | < 1 × 1010grad |a|, b, c < 1 × 10100 0 < b, c |x| < 1 × 10100 Sexagesimal display: |x| < 1 × 107 x > 0: -1 × 10100 < y log x < 100 x = 0 : y > 0 x < 0 : y = n, -2-nm-+-1 (m, n are integers) However; -1 × 10100 < y log |x| < 100 Internal digits 15 digits " " " Precision Notes As a rule, precision is ±1 at the 10th digit.* " However, for tan 90(2n+1): DEG 2(2n+1): RAD |θ | ≠ 100(2n+1): GRA " " • Complex numbers can be used as arguments. y > 0 : x ≠ 0 -1 × 10100 < -1x- logy < 100 y = 0 : x > 0 xy y < 0 : x = 2n+1, 2--nm-+-1 (m ≠ 0; m, n are integers) " However; -1 × 10100 < -1x- log |y| < 100 " • Complex numbers can be used as arguments. Total of integer, numerator a b/c and denominator must be within 10 digits (includes " " division marks). * For a single calculation, calculation error is ±1 at the 10th digit. (In the case of exponential display, calculation error is ±1 at the last significant digit.) Errors are cumulative in the case of consecutive calculations, which can also cause them to become large. (This is also true of internal consecutive calculations that are performed in the case of ^(xy), x y, x!, 3 x, nPr, nCr, etc.) In the vicinity of a function's singular point and point of inflection, errors are cumulative and may become large. 20050401