Manually Deployed and Commissioned Catalyst 6506 Switch
View all Cisco 6504-E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Deployment and Commissioning Process Chapter 4 Deploying the C65/76M Figure 4-16 Manually Deployed and Commissioned Catalyst 6506 Switch If an error is encountered when the object is commissioned, the Network Element object might go into the Mismatched or Lostcomms state and an alarm would be raised. The Network Element is placed in the Mismatched state if the IP address specified during the deployment wizard does not correspond to the device type that was deployed. If this occurs, the Network Element object must be deleted from CEMF and redeployed with the correct IP address or type. The Network Element is placed in the Lostcomms state if the SNMP read community string specified in during the deployment wizard is incorrect. If this occurs, open the Network Element dialog box, decommission the Network Element object, go to the SNMP tab (Figure 4-6) and enter the correct SNMP read community, and then recommission the Network Element object. 4-20 Cisco 6500/7600 Series Manager User Guide