Compaq Armada V300 Compaq Armada E500 and Armada V300 Series Maintenance and S - Page 56
Table 2-9, Problem, Possible Cause, Solution, FNOTE
View all Compaq Armada V300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Table 2-9 continued Problem Possible Cause Solution Battery charge does not last very long (continued). Battery was exposed Move the computer to a to extremely cold warmer place and temperatures. recharge the battery pack. NOTE: The recommended operating temperature range for the battery is from 10°C to 40°C (50°F to 104°F). The recommended storage temperature range for the battery is from 0°C to 30°C (32°F to 86°F). Battery conservation Reset the battery is disabled or set to conservation level. drain. An external device is Turn off or remove any draining the battery. external device or PC Cards when not in use. Battery gauge is inaccurate and requires recalibration. Recalibrate the gauge. Date and time must be set every time computer is turned on. The real time clock (RTC) battery has reached the end of its useful life. Replace the RTC battery (refer to Section 5.10). Battery gauge seems The battery pack inaccurate. needs calibration. Recalibrate the battery. The battery pack has Replace the battery pack. reached the end of its useful life. Battery pack is warm Warming occurs after charging. during charging. No action is required. Troubleshooting 2-21