Danby DPAC8KDB Product Manual - Page 13
Troubleshooting
View all Danby DPAC8KDB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
TROUBLESHOOTING Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby's Toll Free Number for assistance. C PROBLEM • Unit does not work POSSIBLE CAUSE • Power is out • The plug is not plugged in properly • The full-tank indicator is ON; tank is full • Current leaking or pressing test button on LCDI plug SOLUTION • Wait for power to return • Plug in properly • Remove drain water from the drain tank • Press the reset button after resolving problem • Unit suddenly stops during operation • Unit runs intermittently • Unit functions but the room is not cooled • Condensed water spills out when moving the unit ... • Indoor set temperature has been reached • The preset time is up • The full-tank indicator is ON; tank is full • Malfunction • Surrounding temperature is too high/low • Exhaust duct hose is blocked • Window or door is open in room • There is a heat source or too many people in the room • Air intake grill is clogged • Filter is too dirty • Temperature setting is too high • The tank is nearly full • Reset the temperature level • Reset the timer • Remove drain water from the drain tank • Contact your dealer • This is normal • Check the duct hose • Close all windows/doors • Move any heat sources from room • Clean air intake grill • Replace the filter • Lower temp. setting • Remove drain plug on rear bottom and drain out water 2 11