Danby DWC508BLS Product Manual - Page 4
Installtion Intructions - wine
View all Danby DWC508BLS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
INSTALLTION INTRUCTIONS TOOLS YOU WILL NEED FOR YOUR SAFETY: While performing installations described in this section, gloves, safety glasses, or goggles should be worn. Safety Glasses Gloves Drill & Hole Saw set Level Flashlight Carpenters Square Measuring Tape PREPARING THE ELECTRICAL REQUIREMENTS: The appliance must be connected to an ENCLOSURE individual, properly grounded electrical outlet, protected by a 15 or 20 ampere circuit breaker or time delay fuse. • It is recommended that you do not install the wine cooler into a corner (i.e. directly beside a wall). This is to allow the door to have a greater then 90° opening swing. A limited door swing may lead to damaging the door gasket. • The rough cabinet opening must be on a level floor area and at least 24" deep by 24" wide. The opening should also have a height of at least 34 3/4". • The electrical oulet may be positioned from within either side of the adjacent cabinetry, or the rear of the shaded area (as shown in Fig E). • If the electrical outlet is located inside the adjacent cabinetry, cut a 1-1/2" diameter hole to admit the power cord. If the cabinet wall is metal, the hole edge must be covered with a bushing or grommet. 34 3/4" From Underside of Countertop to Floor 1 1- /2" dia. hole *if electical outlet is in adjacent cabinetry 24" Min. 2" Electrical Access 6" Cabinets Square and Plumb 24" Fig E 3