Dell C1048P Port Extender Networking C1048P Installation Guide
Dell C1048P Port Extender Manual
View all Dell C1048P Port Extender manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell C1048P Port Extender manual content summary:
- Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 1
Dell Networking C1048P Installation Guide Regulatory Model: C1048P - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 2
use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 3
to install a C1048P port extender in a rack. For complete information about C1048P installation and configuration, refer to these documents: Table 1. C1048P Documentation Information Documentation Hardware installation, power-up, and initial software configuration instructions Dell Networking - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 4
PEs (standalone and stacked) to a C9010 switch. Deployed as a port extender, the C1048P extends the switching capability of the C9010. The C1048P uses a standards-based tagging mechanism coupled with virtual port technology to multiplex and demultiplex data-plane traffic to and from the C9010, which - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 5
baud. The default settings are 9600 baud rate, 8 data bits, No Parity, 1 Stop Bit, and No Flow Control. 2. USB port The Type-A, female USB port supports a USB 2.0-compliant flash memory drive. The C1048P can read or write to a flash drive formatted as FAT-32. Use a USB flash drive to copy files and - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 6
The 48 Gigabit Ethernet (10BASE-T, 100BASE-TX, 1000BASE-T) RJ-45 ports connect to downstream servers and edge devices. These ports support auto-negotiation for speed and duplex transmission. C1048P Gigabit Ethernet ports are numbered 1 to 48. NOTE: Dell Networking does not recommend that you connect - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 7
LEDs The following table describes 10/100/1000BASE-T port LEDs (items 1 and 2 in Figure 2). C1048P 10/100/1000BASE-T Port LEDs LED Description Link Link speed on port • Off: No link is up. • Solid green: The port is operating at 1000 Mbps. • Solid yellow: The port is operating at 10/100 Mbps - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 8
The PE is operating as a stack master or in standalone mode. NOTE: While the C1048P is booting up in standalone or stacking mode, the Stack Master LED is solid green. SFP : Link is up and operating at maximum 10G port speed. SFP+ activity status • Off: No data link activity • Flashing green: Link - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 9
on its back panel. Stack port 1 is on top; stack port 2 is on the bottom. You can stack up to eight C1048P PEs using the mini-SAS ports on the back panel. A C1048P PE supports stacking only with other C1048P PEs. When you connect multiple C1048P PEs using the stack ports, the PEs operate as a single - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 10
data link activity. • Flashing green: Stack link is up and transmitting/receiving data. Before You Start: Site Preparation Before installing the C1048P port extender, make sure that your installation site meets these requirements: • Clearance: There is adequate space in front of the PE so you can - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 11
as fans and blowers in the switch, can draw dust and other particles causing contaminant buildup inside the chassis, which can result in system malfunction. C1048P Hardware Description 11 - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 12
must be able to support the weight of the C1048P and the PE cables. The C1048P ships with four self-adhesive rubber pads. 1. When installing the C1048P on a flat air flow - Install the port extender in the rack so that the front-to-back airflow (I/O ports to PSU) is not obstructed. 12 Installing - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 13
port extender with the rear panel facing in the downward position. Installing a Rack Mount Tray (Optional) You can use a rack mount tray to support the weight of the C1048P in a 4-post rack. You must order the tray separately. To install a rack mount tray in a 4-post rack, follow the instructions - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 14
in a rack: 1. Align the holes on the right rack-mount bracket with the holes on the right side (facing you) of the C1048P. 2. Secure the bracket (item 3 in Figure 6) to the chassis by tightening the screws (item 2 in Figure 6) provided with the mount bracket. Figure 6. Attaching Mount Brackets - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 15
to a C9010 Switch The C1048P port extender has two 10G SFP+ ports on the front panel (see Figure 2). The two SFP+ ports provide 10GbE uplinks to a C9010 switch with SFP+ transceivers. At least one 10GbE SFP+ uplink is required to connect to a C9010 switch. NOTE: A C1048P can connect to a C9010 - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 16
to act as a single port extender. You can stack up to eight C1048Ps using the stack ports on the back panel. C1048P stack ports support the Serial Attached SCSI (SAS) protocol and operate as mini-SAS ports. The C1048P supports stacking only with other C1048P port extenders. The stacked PEs operate - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 17
ring topology with the following physical connections between port extenders. The PEs are numbered Unit 0 to Unit 2. After you power on the stack units, the Stack Master LED on the C1048P that is elected master displays solid green. • The bottom mini-SAS port on the top unit is connected to the top - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 18
in the Safety and Regulatory Information manual and the safety information for C9000 Series switches that connect to the C1048P. The C1048P has one internal power supply. The AC and DC power connectors are on the back panel (see Back Panel). To power up a C1048P, connect it to an AC power - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 19
tag or 11-digit express service code of your C1048P and click Submit. To view the service tag or express service code on a C1048P, pull out the tag (item 1 in Figure 9) on the upper left side of the back panel. • To receive additional kinds of technical support, click Contact Us. On the Contact - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 20
Figure 9. C1048P Service Tag 20 Dell Networking Support - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 21
5 Technical Specifications The following tables describe the technical specifications for the C1048P port extender. Table 3. Chassis Physical Design Parameter Specifications Height 1.7 inches (4.35 cm) Width 17.32 inches (44 cm) Depth Chassis weight 15.23 inches (38.7 cm) 15 - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 22
Parameter Maximum thermal output Specifications 1,017 BTU/hr @ 110V (1.738W - 1,440W PoE = 298W switch power) 22 Technical Specifications - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 23
6 Agency Compliance The C1048P complies with the following safety and agency requirements. European Union EMC Directive Conformance Statement This product is in conformity with the protection requirements of EU - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 24
For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. WARNING: Use the AC power cords with Dell Networking equipment only. Do - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 25
2nd Edition or later • EN 60825-1, 1st Edition or later • EN 60825-1 Safety of Laser Products-Part 1: Equipment Classification Requirements and User's Guide • EN 60825-2 Safety of Laser Products-Part 2: Safety of Optical Fibre Communication Systems • FDA Regulation 21CFR 1040.10 and 1040.11 • IEC - Dell C1048P Port Extender | Networking C1048P Installation Guide - Page 26
Dell Networking offers a variety of product return programs and services in several countries to assist equipment owners in recycling their on Dell Networking product recycling offerings, see the WEEE Recycling instructions on iSupport. For more information, contact the Dell Networking Technical