Dell Force10 S25N-S50N Installing S25N and S25V Systems - Page 29
Supplying Power, S25V, In addition, Force10 provides, as an option
View all Dell Force10 S25N-S50N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Supplying Power Supply power to the units in a stack only after they are mounted and the stack ports are connected. There is no on/off switch, and the stack members partly determine the stack management unit from the order in which they come on-line (see below). Danger: To prevent electrical shock, make sure the switch is grounded properly. If you do not ground your equipment correctly, excessive emissions can result. Use a qualified electrician to ensure that the power cables meet your local electrical requirements. See other relevant cautions in Information Symbols and Warnings on page 7. S25N The S25N has two AC receptacles in the rear of the unit (see Figure 3 on page 10). The system can use either power source independently, or act in load-sharing mode. Connect the supplied AC power cord first to either receptacle (on the right as you face the rear of the system) and then to the power source (see AC Power Requirements on page 50). Ensure that the cord is secure. If you connect both AC power supplies, ideally you would connect them to separate circuits. S25V The S25V has both an AC (3-prong plug receptacle) and a DC (-48V terminal-type) connection on the back of the unit (see Figure 2 on page 10). Each power source can be used independently or in load-sharing combination. In other words, you have three options for providing power to the switch - AC only, DC only, or using both AC and DC sources. In addition, Force10 provides, as an option, an external 470W DC Redundant Power Supply Unit (PSU), which can be connected in either load-sharing mode or current-sharing mode. For details, see Chapter 4, Installing Backup Power, on page 31. To use AC only, connect the supplied AC power cord first to the switch (receptacle on the right as you face the rear of the unit) and then to the power source (see AC Power Requirements on page 50). Connect the plug to the AC receptacle at the right rear of the switch, making sure that the power cord is secure. For DC power, you must provide your own cables to connect to the power source. Cables must be sized for 11.5 A service at no more than -48 VDC input (per NEC in the United States; internationally; follow local safety codes.). Before you make the cable connections, apply a coat of antioxidant paste to unplated metal contact surfaces. File unplated connectors, braided straps, and bus bars to a shiny finish. 1 Make sure that the remote power source (the circuit breaker panel) is in the OFF position. 2. Remove the safety cover from the DC terminal block. 3. Connect the grounding cable to the FG terminal first, then connect the opposite end to the appropriate grounding point at your site to ensure an adequate unit ground. 4. Connect the -48 V and -48 V RTN (Return) cables to the switch terminals and then to the remote power sources. For the Current Sharing terminal, see Chapter 4, Installing Backup Power, on page 31. 5. Replace the safety covers on the DC terminal block. Installing S25N and S25V Systems 29