Dell OptiPlex 380 Guidebook - Page 18
System Level Environmental and Operating Conditions
View all Dell OptiPlex 380 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
DELL™ OPTIPLEX™ 380 TECHNICAL GUIDEBOOK MT Length inches/centimeters Dual Full Height Riser with 2 PCI connectors (HxL) Height inches/centimeters Length inches/centimeters * Card length can be longer than standard Half-Length Card but cannot be a Full-Length Card. ** 6.9/17.53 in/cm is longer than the standard Half-Length Card DT 6.9/17.53** 1 4.376/11.115 6.9/17.53** SFF System Level Environmental and Operating Conditions MT DT SFF Temperature Operating 10°to 35°C (50°to 95°F) Non-Operating -40°to 65°C (-40°to 149°F) Relative Humidity Operating (Noncondensing) 20 to 80 %* (*Max Wet bulb temperature= 29 °C) Non-Operating (Noncondensing) 5 to 95 %+ (+Max Wet bulb temperature= 38 °C) Maximum vibration Operating Non-Operating 0.25 G at 3 to 200 Hz at 0.5 octave/min 0.5 G at 3 to 200 Hz at 1 octave/min Maximum Shock Operating Bottom half-sine pulse with a change in velocity of 50.8 cm/sec (20 inches/sec) Non-Operating 27-G faired square wave with a velocity change of 508 cm/sec (200 inches/sec) Maximum Altitude Operating Non-Operating -15.2 to 3048 m (-50 to 10,000 ft) -15.2 to 10,668 m (-50 to 35,000 ft) 18