Dell PowerEdge C8000 Dell PowerEdge C8220 and C8220X Using the Baseboard Ma - Page 59

Table 1-41., SDR Repository Commands NETFUN: 0AH, Command, NetFn, Supported, Table 1-42., LAN

Page 59 highlights

FILE LOCATION: D:\Projects\User Guide\Server\Dell\Zeus\HOM\BMC Manual\BMC\C8000_BMC_HOM_section1.fm Table 1-41. SDR Repository Commands (NETFUN: 0AH) Command NetFn CMD O/M Get SDR Repository Info Storage 20h M Get SDR Repository Allocation Info Storage 21h O Reserve SDR Repository Storage 22h M Get SDR Storage 23h M Add SDR Storage 24h M Partial ADD SDR Storage 25h O Delete SDR Storage 26h O Clear SDR Repository Storage 27h M Get SDR Repository Time Storage 28h O Set SDR Repository Time Storage 29h O Enter SDR Repository Update Mode Storage 2Ah O Exit SDR Repository Update Mode Storage 2Bh O Run Initialization Agent Storage 2Ch O Supported Yes No Yes Yes No Yes No Yes Yes Yes No No Yes Table 1-42. LAN Commands (NETFUN: 0CH) Command Set LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported.) Get LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported.) Suspend BMC ARP Get IP/UDP/RMCP Statistics NetFn CMD O/M Transport 01h M Transport 02h M Transport 03h O Transport 04h O Supported Yes Yes No No 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

59
FILE LOCATION:
D:\Projects\User Guide\Server\Dell\Zeus\HOM\BMC
Manual\BMC\C8000_BMC_HOM_section1.fm
Table 1-41.
SDR Repository Commands (NETFUN: 0AH)
Command
NetFn
CMD
O/M
Supported
Get SDR Repository Info
Storage
20h
M
Yes
Get SDR Repository Allocation Info
Storage
21h
O
No
Reserve SDR Repository
Storage
22h
M
Yes
Get SDR
Storage
23h
M
Yes
Add SDR
Storage
24h
M
No
Partial ADD SDR
Storage
25h
O
Yes
Delete SDR
Storage
26h
O
No
Clear SDR Repository
Storage
27h
M
Yes
Get SDR Repository Time
Storage
28h
O
Yes
Set SDR Repository Time
Storage
29h
O
Yes
Enter SDR Repository Update Mode
Storage
2Ah
O
No
Exit SDR Repository Update Mode
Storage
2Bh
O
No
Run Initialization Agent
Storage
2Ch
O
Yes
Table 1-42.
LAN Commands (NETFUN: 0CH)
Command
NetFn
CMD
O/M
Supported
Set LAN Configuration Parameters
(
Note:
Parameter 9 and 25 are not
supported.)
Transport
01h
M
Yes
Get LAN Configuration Parameters
(
Note:
Parameter 9 and 25 are not
supported.)
Transport
02h
M
Yes
Suspend BMC ARP
Transport
03h
O
No
Get IP/UDP/RMCP Statistics
Transport
04h
O
No